Tanner Preserve AV
Home / Venues / Manchester Central / The Gallery

The Gallery at Manchester Central

Published dimensions

The Gallery is 48.5 x 15.4 m (159 x 51 ft), 747 m² (8,040 sq ft), with a 6.5 m (21 ft) ceiling.

Open in 3D previz

Plan view

48.5 m / 159 ft15.4 m / 51 ft grid 5 m

LED wall that fits

Under a 6.5 m ceiling with 1.5 m trim and 0.3 m clearance you get 9 rows of 500 mm tile flown. Along the 48.5 m wall a Absen A2 Pro wall runs 77 x 9 (12936 x 1512 px, 6,930 kg, 128.2 kW).

PanelPitchWall (cols x rows)SizeResolutionWeightPower (max)
9thPanel DW1.9 S Pro1.875 mm64 x 14 = 89638.4 x 4.7 m20480 x 25204,301 kg / 9,482 lb227.6 kW, 1094 A @ 208 V
Absen A2 Pro2.97 mm77 x 9 = 69338.5 x 4.5 m12936 x 15126,930 kg / 15,278 lb128.2 kW, 616 A @ 208 V
Absen A3 Pro3.9 mm77 x 9 = 69338.5 x 4.5 m9856 x 11526,584 kg / 14,514 lb110.9 kW, 533 A @ 208 V

Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.

Seating estimate

After a 12 x 7 m stage, The Gallery holds about 1,473 theater seats, 602 banquet seats at rounds of 10, or 414 classroom seats. Back row in theater is roughly 41.5 m from the downstage edge; the previz checks whether the bottom of the wall clears the heads in front.

Other rooms at Manchester Central

Published dimensions (source), fetched 2026-09-05. All rooms at Manchester Central · Venues in Manchester