Alliant Energy Center
Alliant Energy Center in Madison lists 10 event spaces totaling 22,428 m² (241,415 sq ft). The largest is Halls A-D at 64 x 146.3 m (210 x 480 ft) with a 9.1 m (30 ft) ceiling. The tallest ceiling on the property is 29.3 m (96 ft).
Open Halls A-D in 3D previzRooms
| Room | Floor | L x W (m) | L x W (ft) | Area | Ceiling | Rig pts | Data |
|---|---|---|---|---|---|---|---|
| Halls A-D | 64 x 146.3 | 210 x 480 | 9,363 m² / 100,785 sq ft | 9.1 m / 30 ft | Published dimensions | ||
| Coliseum | 78.8 x 78.8 | 259 x 259 | 6,209 m² / 66,837 sq ft | 29.3 m / 96 ft | Published dimensions | ||
| Lobby | 13.7 x 173.7 | 45 x 570 | 2,380 m² / 25,615 sq ft | 9.1 m / 30 ft | Published dimensions | ||
| Arena Building | 30.5 x 67.1 | 100 x 220 | 2,047 m² / 22,028 sq ft | 9.1 m / 30 ft | Published dimensions | ||
| Mendota 1-4 | 18.3 x 43.9 | 60 x 144 | 803 m² / 8,648 sq ft | 3.7 m / 12 ft | Published dimensions | ||
| Mendota 5–8 | 13.4 x 43.9 | 44 x 144 | 588 m² / 6,332 sq ft | 3.4 m / 11 ft | Published dimensions | ||
| Atrium | 23.5 x 23.2 | 77 x 76 | 545 m² / 5,868 sq ft | 3.7 m / 12 ft | Published dimensions | ||
| Lake Rooms | 36.6 x 9.8 | 120 x 32 | 359 m² / 3,861 sq ft | 4.7 m / 15 ft | Published dimensions | ||
| Board Room | 9.8 x 9.1 | 32 x 30 | 89 m² / 960 sq ft | 4.7 m / 15 ft | Published dimensions | ||
| Madison Room | 4.9 x 9.1 | 16 x 30 | 45 m² / 480 sq ft | 3 m / 10 ft | Published dimensions |
What fits in Halls A-D
With a 9.1 m ceiling, a flown wall of Absen A2 Pro (2.97 mm) runs 234 tiles wide by 14 high (3276 tiles, 117 x 7 m, 39312 x 2352 px) once you keep 1.5 m of trim under the bottom edge. That wall weighs about 32,760 kg and draws up to 606.1 kW (2914 A at 208 V). Floor space after a 12 x 7 m stage seats roughly 20,620 theater, 8,435 banquet, or 5,799 classroom. The previz lets you move the wall, change the tile, and check sightlines from the back row.
| Panel | Pitch | Wall (cols x rows) | Size | Resolution | Weight | Power (max) |
|---|---|---|---|---|---|---|
| 9thPanel DW1.9 S Pro | 1.875 mm | 195 x 21 = 4095 | 117 x 7.1 m | 62400 x 3780 | 19,656 kg / 43,334 lb | 1040.1 kW, 5001 A @ 208 V |
| Absen A2 Pro | 2.97 mm | 234 x 14 = 3276 | 117 x 7 m | 39312 x 2352 | 32,760 kg / 72,223 lb | 606.1 kW, 2914 A @ 208 V |
| Absen A3 Pro | 3.9 mm | 234 x 14 = 3276 | 117 x 7 m | 29952 x 1792 | 31,122 kg / 68,612 lb | 524.2 kW, 2520 A @ 208 V |
Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.
Planning notes
No rigging point data is published for this venue yet; plan on ground-supported LED or ask the venue for its rigging plot. 2 of the 10 rooms sit under 3.5 m, which rules out flown LED there and limits ground-stacked walls to about 6 rows of 500 mm tile.
Data source
Published dimensions. Dimensions from the venue's published meeting-space specifications (source). Rooms drawn as boxes use published length x width; square rooms were derived from published area only, so treat their shape as approximate. Venue managers: send a floor plan to upgrade your listing to production-ready.