Tanner Preserve AV
Home / Venues / Macon / Anderson Conference Center

Anderson Conference Center

Published dimensionsMacon

Anderson Conference Center in Macon lists 7 event spaces totaling 1,596 m² (17,180 sq ft). The largest is Anderson Ballroom at 28.3 x 28.3 m (93 x 93 ft) with a 3.1 m (10 ft) ceiling. The tallest ceiling on the property is 3.1 m (10 ft).

Open Anderson Ballroom in 3D previz

Rooms

RoomFloorL x W (m)L x W (ft)AreaCeilingRig ptsData
Anderson Ballroom28.3 x 28.393 x 93801 m² / 8,621 sq ft3.1 m / 10 ftPublished dimensions
Boston Conference Room16 x 1652 x 52256 m² / 2,756 sq ft3.1 m / 10 ftPublished dimensions
Boston III Conference Room12.2 x 12.240 x 40149 m² / 1,602 sq ft3.1 m / 10 ftPublished dimensions
Morgan Room10.6 x 10.635 x 35112 m² / 1,210 sq ft3.1 m / 10 ftPublished dimensions
Boston 1 Conference Room10.5 x 10.534 x 34110 m² / 1,187 sq ft3.1 m / 10 ftPublished dimensions
Preston II Conference Room9.5 x 9.531 x 3190 m² / 972 sq ft3.1 m / 10 ftPublished dimensions
Preston I Conference Room8.8 x 8.829 x 2977 m² / 833 sq ft3 m / 10 ftPublished dimensions

What fits in Anderson Ballroom

With a 3.1 m ceiling, a flown wall of Absen A2 Pro (2.97 mm) runs 45 tiles wide by 2 high (90 tiles, 22.5 x 1 m, 7560 x 336 px) once you keep 1.5 m of trim under the bottom edge. That wall weighs about 900 kg and draws up to 16.7 kW (80 A at 208 V). Floor space after a 12 x 7 m stage seats roughly 1,593 theater, 651 banquet, or 448 classroom. The previz lets you move the wall, change the tile, and check sightlines from the back row.

PanelPitchWall (cols x rows)SizeResolutionWeightPower (max)
9thPanel DW1.9 S Pro1.875 mm37 x 3 = 11122.2 x 1 m11840 x 540533 kg / 1,175 lb28.2 kW, 136 A @ 208 V
Absen A2 Pro2.97 mm45 x 2 = 9022.5 x 1 m7560 x 336900 kg / 1,984 lb16.7 kW, 80 A @ 208 V
Absen A3 Pro3.9 mm45 x 2 = 9022.5 x 1 m5760 x 256855 kg / 1,885 lb14.4 kW, 69 A @ 208 V

Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.

Planning notes

No rigging point data is published for this venue yet; plan on ground-supported LED or ask the venue for its rigging plot. 7 of the 7 rooms sit under 3.5 m, which rules out flown LED there and limits ground-stacked walls to about 6 rows of 500 mm tile.

Data source

Published dimensions. Dimensions from the venue's published meeting-space specifications (source). Rooms drawn as boxes use published length x width; square rooms were derived from published area only, so treat their shape as approximate. Venue managers: send a floor plan to upgrade your listing to production-ready.

More venues in Macon · All venues