Tanner Preserve AV
Home / Venues / Macedon / Lancemore Macedon Ranges

Lancemore Macedon Ranges

Published dimensionsMacedon

Lancemore Macedon Ranges in Macedon lists 6 event spaces totaling 644 m² (6,935 sq ft). The largest is Dining Room at 15.4 x 15.4 m (51 x 51 ft) with a 3.1 m (10 ft) ceiling. The tallest ceiling on the property is 3.1 m (10 ft).

Open Dining Room in 3D previz

Rooms

RoomFloorL x W (m)L x W (ft)AreaCeilingRig ptsData
Dining Room15.4 x 15.451 x 51237 m² / 2,553 sq ft3.1 m / 10 ftPublished dimensions
Allenwood10.4 x 10.434 x 34108 m² / 1,165 sq ft3.1 m / 10 ftPublished dimensions
Springfield10.1 x 10.133 x 33102 m² / 1,098 sq ft3.1 m / 10 ftPublished dimensions
Hume9.5 x 9.531 x 3190 m² / 972 sq ft3.1 m / 10 ftPublished dimensions
Dairy7.3 x 7.324 x 2453 m² / 574 sq ft3.1 m / 10 ftPublished dimensions
Goldie7.3 x 7.324 x 2453 m² / 574 sq ft3.1 m / 10 ftPublished dimensions

What fits in Dining Room

With a 3.1 m ceiling, a flown wall of Absen A2 Pro (2.97 mm) runs 24 tiles wide by 2 high (48 tiles, 12 x 1 m, 4032 x 336 px) once you keep 1.5 m of trim under the bottom edge. That wall weighs about 480 kg and draws up to 8.9 kW (43 A at 208 V). Floor space after a 12 x 7 m stage seats roughly 340 theater, 139 banquet, or 95 classroom. The previz lets you move the wall, change the tile, and check sightlines from the back row.

PanelPitchWall (cols x rows)SizeResolutionWeightPower (max)
9thPanel DW1.9 S Pro1.875 mm20 x 3 = 6012 x 1 m6400 x 540288 kg / 635 lb15.2 kW, 73 A @ 208 V
Absen A2 Pro2.97 mm24 x 2 = 4812 x 1 m4032 x 336480 kg / 1,058 lb8.9 kW, 43 A @ 208 V
Absen A3 Pro3.9 mm24 x 2 = 4812 x 1 m3072 x 256456 kg / 1,005 lb7.7 kW, 37 A @ 208 V

Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.

Planning notes

No rigging point data is published for this venue yet; plan on ground-supported LED or ask the venue for its rigging plot. 6 of the 6 rooms sit under 3.5 m, which rules out flown LED there and limits ground-stacked walls to about 6 rows of 500 mm tile.

Data source

Published dimensions. Dimensions from the venue's published meeting-space specifications (source). Rooms drawn as boxes use published length x width; square rooms were derived from published area only, so treat their shape as approximate. Venue managers: send a floor plan to upgrade your listing to production-ready.

More venues in Macedon · All venues