Published dimensions

Meeting Room 502A is 26.2 x 16.8 m (86 x 55 ft), 440 m² (4,738 sq ft), with a 4 m (13 ft) ceiling.

Open in 3D previz

Plan view

26.2 m / 86 ft16.8 m / 55 ft grid 5 m

LED wall that fits

Under a 4 m ceiling with 1.5 m trim and 0.3 m clearance you get 4 rows of 500 mm tile flown. Along the 26.2 m wall a Absen A2 Pro wall runs 41 x 4 (6888 x 672 px, 1,640 kg, 30.3 kW).

PanelPitchWall (cols x rows)SizeResolutionWeightPower (max)
9thPanel DW1.9 S Pro1.875 mm34 x 6 = 20420.4 x 2 m10880 x 1080979 kg / 2,159 lb51.8 kW, 249 A @ 208 V
Absen A2 Pro2.97 mm41 x 4 = 16420.5 x 2 m6888 x 6721,640 kg / 3,616 lb30.3 kW, 146 A @ 208 V
Absen A3 Pro3.9 mm41 x 4 = 16420.5 x 2 m5248 x 5121,558 kg / 3,435 lb26.2 kW, 126 A @ 208 V

Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.

Seating estimate

After a 12 x 7 m stage, Meeting Room 502A holds about 791 theater seats, 323 banquet seats at rounds of 10, or 222 classroom seats. Back row in theater is roughly 19.2 m from the downstage edge; the previz checks whether the bottom of the wall clears the heads in front.