Olympia
Olympia in London lists 6 event spaces totaling 10,390 m² (111,833 sq ft). The largest is ICC Level 1 (Whole Floor) at 70.7 x 70.7 m (232 x 232 ft) with a 13.7 m (45 ft) ceiling. The tallest ceiling on the property is 13.7 m (45 ft).
Open ICC Level 1 (Whole Floor) in 3D previzRooms
| Room | Floor | L x W (m) | L x W (ft) | Area | Ceiling | Rig pts | Data |
|---|---|---|---|---|---|---|---|
| ICC Level 1 (Whole Floor) | 70.7 x 70.7 | 232 x 232 | 4,999 m² / 53,803 sq ft | 13.7 m / 45 ft | Published dimensions | ||
| ICC Level 1 - Central Hall | 51.6 x 51.6 | 169 x 169 | 2,663 m² / 28,660 sq ft | 13.7 m / 45 ft | Published dimensions | ||
| ICC Level 2 (Whole Floor) | 35.3 x 35.3 | 116 x 116 | 1,246 m² / 13,413 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| ICC Level 1 - Auditorium | 23.8 x 23.8 | 78 x 78 | 566 m² / 6,097 sq ft | 13.7 m / 45 ft | Published dimensions | ||
| ICC Level 2 - Large Conference Room | 21.6 x 21.6 | 71 x 71 | 467 m² / 5,022 sq ft | 5.8 m / 19 ft | Published dimensions | ||
| ICC Level 2M - Networking/Catering space | 21.2 x 21.2 | 70 x 70 | 449 m² / 4,837 sq ft | 2.6 m / 9 ft | Published dimensions |
What fits in ICC Level 1 (Whole Floor)
With a 13.7 m ceiling, a flown wall of Absen A2 Pro (2.97 mm) runs 113 tiles wide by 23 high (2599 tiles, 56.5 x 11.5 m, 18984 x 3864 px) once you keep 1.5 m of trim under the bottom edge. That wall weighs about 25,990 kg and draws up to 480.8 kW (2312 A at 208 V). Floor space after a 12 x 7 m stage seats roughly 10,921 theater, 4,467 banquet, or 3,071 classroom. The previz lets you move the wall, change the tile, and check sightlines from the back row.
| Panel | Pitch | Wall (cols x rows) | Size | Resolution | Weight | Power (max) |
|---|---|---|---|---|---|---|
| 9thPanel DW1.9 S Pro | 1.875 mm | 94 x 35 = 3290 | 56.4 x 11.8 m | 30080 x 6300 | 15,792 kg / 34,815 lb | 835.7 kW, 4018 A @ 208 V |
| Absen A2 Pro | 2.97 mm | 113 x 23 = 2599 | 56.5 x 11.5 m | 18984 x 3864 | 25,990 kg / 57,298 lb | 480.8 kW, 2312 A @ 208 V |
| Absen A3 Pro | 3.9 mm | 113 x 23 = 2599 | 56.5 x 11.5 m | 14464 x 2944 | 24,691 kg / 54,433 lb | 415.8 kW, 1999 A @ 208 V |
Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.
Planning notes
No rigging point data is published for this venue yet; plan on ground-supported LED or ask the venue for its rigging plot. 2 of the 6 rooms sit under 3.5 m, which rules out flown LED there and limits ground-stacked walls to about 6 rows of 500 mm tile.
Data source
Published dimensions. Dimensions from the venue's published meeting-space specifications (source). Rooms drawn as boxes use published length x width; square rooms were derived from published area only, so treat their shape as approximate. Venue managers: send a floor plan to upgrade your listing to production-ready.