Tanner Preserve AV
Home / Venues / London / London Stadium

London Stadium

Published dimensionsLondon

London Stadium in London lists 11 event spaces totaling 2,977 m² (32,044 sq ft). The largest is The Boleyn at 27.7 x 27.7 m (91 x 91 ft) with a 3.1 m (10 ft) ceiling. The tallest ceiling on the property is 3.1 m (10 ft).

Open The Boleyn in 3D previz

Rooms

RoomFloorL x W (m)L x W (ft)AreaCeilingRig ptsData
The Boleyn27.7 x 27.791 x 91767 m² / 8,259 sq ft3.1 m / 10 ftPublished dimensions
The Great Briton21.2 x 21.270 x 70449 m² / 4,837 sq ft3.1 m / 10 ftPublished dimensions
The Academy18.3 x 18.360 x 60335 m² / 3,605 sq ft3.1 m / 10 ftPublished dimensions
The Forge18 x 1859 x 59324 m² / 3,488 sq ft3.1 m / 10 ftPublished dimensions
North Clubhouse17.9 x 17.959 x 59320 m² / 3,449 sq ft3.1 m / 10 ftPublished dimensions
The Arnold Hills17.8 x 17.858 x 58317 m² / 3,410 sq ft3.1 m / 10 ftPublished dimensions
The Royal East16.7 x 16.755 x 55279 m² / 3,002 sq ft3.1 m / 10 ftPublished dimensions
The Deck8.8 x 8.829 x 2977 m² / 833 sq ft3.1 m / 10 ftPublished dimensions
BM67.8 x 7.826 x 2661 m² / 654 sq ft3.1 m / 10 ftPublished dimensions
South Clubhouse5.5 x 5.518 x 1830 m² / 326 sq ft3.1 m / 10 ftPublished dimensions
Boxes4.1 x 4.113 x 1317 m² / 181 sq ft3.1 m / 10 ftPublished dimensions

What fits in The Boleyn

With a 3.1 m ceiling, a flown wall of Absen A2 Pro (2.97 mm) runs 44 tiles wide by 2 high (88 tiles, 22 x 1 m, 7392 x 336 px) once you keep 1.5 m of trim under the bottom edge. That wall weighs about 880 kg and draws up to 16.3 kW (78 A at 208 V). Floor space after a 12 x 7 m stage seats roughly 1,518 theater, 621 banquet, or 427 classroom. The previz lets you move the wall, change the tile, and check sightlines from the back row.

PanelPitchWall (cols x rows)SizeResolutionWeightPower (max)
9thPanel DW1.9 S Pro1.875 mm36 x 3 = 10821.6 x 1 m11520 x 540518 kg / 1,143 lb27.4 kW, 132 A @ 208 V
Absen A2 Pro2.97 mm44 x 2 = 8822 x 1 m7392 x 336880 kg / 1,940 lb16.3 kW, 78 A @ 208 V
Absen A3 Pro3.9 mm44 x 2 = 8822 x 1 m5632 x 256836 kg / 1,843 lb14.1 kW, 68 A @ 208 V

Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.

Planning notes

No rigging point data is published for this venue yet; plan on ground-supported LED or ask the venue for its rigging plot. 11 of the 11 rooms sit under 3.5 m, which rules out flown LED there and limits ground-stacked walls to about 6 rows of 500 mm tile.

Data source

Published dimensions. Dimensions from the venue's published meeting-space specifications (source). Rooms drawn as boxes use published length x width; square rooms were derived from published area only, so treat their shape as approximate. Venue managers: send a floor plan to upgrade your listing to production-ready.

More venues in London · All venues