Published dimensionsLondon

Church House Westminster in London lists 16 event spaces totaling 1,685 m² (18,141 sq ft). The largest is Assembly Hall at 22.8 x 22.8 m (75 x 75 ft) with a 9.7 m (32 ft) ceiling. The tallest ceiling on the property is 12 m (39 ft).

Open Assembly Hall in 3D previz

Rooms

RoomFloorL x W (m)L x W (ft)AreaCeilingRig ptsData
Assembly Hall22.8 x 22.875 x 75520 m² / 5,595 sq ft9.7 m / 32 ftPublished dimensions
Harvey Goodwin15.1 x 15.150 x 50228 m² / 2,454 sq ft3.8 m / 12 ftPublished dimensions
Hoare Memorial Hall15.1 x 15.150 x 50228 m² / 2,454 sq ft6.5 m / 21 ftPublished dimensions
Robert Runcie Room12.7 x 12.742 x 42161 m² / 1,736 sq ft2.4 m / 8 ftPublished dimensions
Bishop Partridge Hall11.5 x 11.538 x 38132 m² / 1,424 sq ft3.9 m / 13 ftPublished dimensions
Convocation Hall9.2 x 9.230 x 3085 m² / 911 sq ft4.8 m / 16 ftPublished dimensions
Abbey Room6.9 x 6.923 x 2348 m² / 512 sq ft4.1 m / 13 ftPublished dimensions
Westminster Room6.9 x 6.923 x 2348 m² / 512 sq ft4.1 m / 13 ftPublished dimensions
Ramsey Room6.3 x 6.321 x 2140 m² / 427 sq ft2.8 m / 9 ftPublished dimensions
Coggan Room6.2 x 6.220 x 2038 m² / 413 sq ft2.8 m / 9 ftPublished dimensions
Temple Room5.8 x 5.819 x 1934 m² / 362 sq ft2.8 m / 9 ftPublished dimensions
Sir Herbert Baker Room5.5 x 5.518 x 1830 m² / 326 sq ft4.1 m / 13 ftPublished dimensions
Bishops’ Robing Room5 x 516 x 1625 m² / 269 sq ft4.2 m / 14 ftPublished dimensions
Jubilee Room5 x 516 x 1625 m² / 269 sq ft4.2 m / 14 ftPublished dimensions
Canterbury Room4.7 x 4.715 x 1522 m² / 238 sq ft3.2 m / 10 ftPublished dimensions
York Room4.7 x 4.715 x 1522 m² / 238 sq ft12 m / 39 ftPublished dimensions

What fits in Assembly Hall

With a 9.7 m ceiling, a flown wall of Absen A2 Pro (2.97 mm) runs 36 tiles wide by 15 high (540 tiles, 18 x 7.5 m, 6048 x 2520 px) once you keep 1.5 m of trim under the bottom edge. That wall weighs about 5,400 kg and draws up to 99.9 kW (480 A at 208 V). Floor space after a 12 x 7 m stage seats roughly 968 theater, 396 banquet, or 272 classroom. The previz lets you move the wall, change the tile, and check sightlines from the back row.

PanelPitchWall (cols x rows)SizeResolutionWeightPower (max)
9thPanel DW1.9 S Pro1.875 mm30 x 23 = 69018 x 7.8 m9600 x 41403,312 kg / 7,302 lb175.3 kW, 843 A @ 208 V
Absen A2 Pro2.97 mm36 x 15 = 54018 x 7.5 m6048 x 25205,400 kg / 11,905 lb99.9 kW, 480 A @ 208 V
Absen A3 Pro3.9 mm36 x 15 = 54018 x 7.5 m4608 x 19205,130 kg / 11,310 lb86.4 kW, 415 A @ 208 V

Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.

Planning notes

No rigging point data is published for this venue yet; plan on ground-supported LED or ask the venue for its rigging plot. 5 of the 16 rooms sit under 3.5 m, which rules out flown LED there and limits ground-stacked walls to about 6 rows of 500 mm tile.

Data source

Published dimensions. Dimensions from the venue's published meeting-space specifications (source). Rooms drawn as boxes use published length x width; square rooms were derived from published area only, so treat their shape as approximate. Venue managers: send a floor plan to upgrade your listing to production-ready.