CCT Venues-Smithfield
CCT Venues-Smithfield in London lists 14 event spaces totaling 742 m² (7,991 sq ft). The largest is The Smithfield Suite at 21.1 x 6.7 m (69 x 22 ft) with a 2.4 m (8 ft) ceiling. The tallest ceiling on the property is 2.4 m (8 ft).
Open The Smithfield Suite in 3D previzRooms
| Room | Floor | L x W (m) | L x W (ft) | Area | Ceiling | Rig pts | Data |
|---|---|---|---|---|---|---|---|
| The Smithfield Suite | 21.1 x 6.7 | 69 x 22 | 141 m² / 1,522 sq ft | 2.4 m / 8 ft | Published dimensions | ||
| Restaurant | 17.6 x 4.8 | 58 x 16 | 85 m² / 910 sq ft | 2.4 m / 8 ft | Published dimensions | ||
| Billingsgate | 12.4 x 6.7 | 41 x 22 | 83 m² / 894 sq ft | 2.4 m / 8 ft | Published dimensions | ||
| Smithfield 1 | 12.4 x 6.7 | 41 x 22 | 83 m² / 894 sq ft | 2.4 m / 8 ft | Published dimensions | ||
| Covent Garden | 8.8 x 6.7 | 29 x 22 | 59 m² / 635 sq ft | 2.4 m / 8 ft | Published dimensions | ||
| Spitalfields | 8.8 x 6.7 | 29 x 22 | 59 m² / 635 sq ft | 2.4 m / 8 ft | Published dimensions | ||
| Smithfield 2 | 8.7 x 6.7 | 29 x 22 | 58 m² / 628 sq ft | 2.4 m / 8 ft | Published dimensions | ||
| Meeting Room 3 | 4.8 x 6.7 | 16 x 22 | 32 m² / 347 sq ft | 2.4 m / 8 ft | Published dimensions | ||
| Camden Lock | 5.6 x 5.7 | 18 x 19 | 32 m² / 343 sq ft | 2.4 m / 8 ft | Published dimensions | ||
| Meeting Room 4 | 4.3 x 6.7 | 14 x 22 | 29 m² / 310 sq ft | 2.4 m / 8 ft | Published dimensions | ||
| Meeting Room 1 | 4.6 x 5.6 | 15 x 18 | 26 m² / 278 sq ft | 2.4 m / 8 ft | Published dimensions | ||
| Meeting Room 5 | 3.7 x 6.7 | 12 x 22 | 25 m² / 267 sq ft | 2.4 m / 8 ft | Published dimensions | ||
| Syndicate A | 4.4 x 3.9 | 14 x 13 | 17 m² / 185 sq ft | 2.4 m / 8 ft | Published dimensions | ||
| Syndicate B | 3.4 x 3.9 | 11 x 13 | 13 m² / 143 sq ft | 2.4 m / 8 ft | Published dimensions |
What fits in The Smithfield Suite
With a 2.4 m ceiling, a flown wall of Absen A2 Pro (2.97 mm) runs 33 tiles wide by 1 high (33 tiles, 16.5 x 0.5 m, 5544 x 168 px) once you keep 1.5 m of trim under the bottom edge. That wall weighs about 330 kg and draws up to 6.1 kW (29 A at 208 V). Floor space after a 12 x 7 m stage seats roughly 127 theater, 52 banquet, or 35 classroom. The previz lets you move the wall, change the tile, and check sightlines from the back row.
| Panel | Pitch | Wall (cols x rows) | Size | Resolution | Weight | Power (max) |
|---|---|---|---|---|---|---|
| 9thPanel DW1.9 S Pro | 1.875 mm | 28 x 1 = 28 | 16.8 x 0.3 m | 8960 x 180 | 134 kg / 296 lb | 7.1 kW, 34 A @ 208 V |
| Absen A2 Pro | 2.97 mm | 33 x 1 = 33 | 16.5 x 0.5 m | 5544 x 168 | 330 kg / 728 lb | 6.1 kW, 29 A @ 208 V |
| Absen A3 Pro | 3.9 mm | 33 x 1 = 33 | 16.5 x 0.5 m | 4224 x 128 | 314 kg / 691 lb | 5.3 kW, 25 A @ 208 V |
Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.
Planning notes
No rigging point data is published for this venue yet; plan on ground-supported LED or ask the venue for its rigging plot. 14 of the 14 rooms sit under 3.5 m, which rules out flown LED there and limits ground-stacked walls to about 6 rows of 500 mm tile. The Smithfield Suite is a long room (3.1:1), so put the wall on the short end and expect the back row to be 21.1 m out; a 2.97 mm pitch holds up at that distance.
Data source
Published dimensions. Dimensions from the venue's published meeting-space specifications (source). Rooms drawn as boxes use published length x width; shapes are as published. Venue managers: send a floor plan to upgrade your listing to production-ready.