King Power Stadium
King Power Stadium in Leicester lists 11 event spaces totaling 3,985 m² (42,889 sq ft). The largest is The Walkers Hall at 22.6 x 47.9 m (74 x 157 ft) with a 3 m (10 ft) ceiling. The tallest ceiling on the property is 3.1 m (10 ft).
Open The Walkers Hall in 3D previzRooms
| Room | Floor | L x W (m) | L x W (ft) | Area | Ceiling | Rig pts | Data |
|---|---|---|---|---|---|---|---|
| The Walkers Hall | 22.6 x 47.9 | 74 x 157 | 1,083 m² / 11,652 sq ft | 3 m / 10 ft | Published dimensions | ||
| Keith Weller Lounge | 22.6 x 39.6 | 74 x 130 | 895 m² / 9,634 sq ft | 3 m / 10 ft | Published dimensions | ||
| Hall 1 (North) | 25.4 x 25.4 | 83 x 83 | 645 m² / 6,945 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Hall 2 (South) | 22.4 x 22.4 | 73 x 73 | 502 m² / 5,401 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Banks Lounge | 37 x 8.5 | 121 x 28 | 315 m² / 3,385 sq ft | 2.6 m / 9 ft | Published dimensions | ||
| Lineker Suite | 13 x 13.5 | 43 x 44 | 176 m² / 1,889 sq ft | 2.6 m / 9 ft | Published dimensions | ||
| Rowley Suite | 11.9 x 11 | 39 x 36 | 131 m² / 1,409 sq ft | 2.6 m / 9 ft | Published dimensions | ||
| Adam Black Suite | 13.3 x 8.9 | 44 x 29 | 118 m² / 1,274 sq ft | 2.6 m / 9 ft | Published dimensions | ||
| Bloomfield Suite | 8.4 x 8.9 | 28 x 29 | 75 m² / 805 sq ft | 2.6 m / 9 ft | Published dimensions | ||
| Chandler Suite | 6.7 x 6.7 | 22 x 22 | 45 m² / 483 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Executive Suite (44) | 1 x 1 | 3 x 3 | 1 m² / 11 sq ft | 3.1 m / 10 ft | Published dimensions |
What fits in The Walkers Hall
With a 3 m ceiling, a flown wall of Absen A2 Pro (2.97 mm) runs 76 tiles wide by 2 high (152 tiles, 38 x 1 m, 12768 x 336 px) once you keep 1.5 m of trim under the bottom edge. That wall weighs about 1,520 kg and draws up to 28.1 kW (135 A at 208 V). Floor space after a 12 x 7 m stage seats roughly 2,218 theater, 907 banquet, or 624 classroom. The previz lets you move the wall, change the tile, and check sightlines from the back row.
| Panel | Pitch | Wall (cols x rows) | Size | Resolution | Weight | Power (max) |
|---|---|---|---|---|---|---|
| 9thPanel DW1.9 S Pro | 1.875 mm | 63 x 3 = 189 | 37.8 x 1 m | 20160 x 540 | 907 kg / 2,000 lb | 48 kW, 231 A @ 208 V |
| Absen A2 Pro | 2.97 mm | 76 x 2 = 152 | 38 x 1 m | 12768 x 336 | 1,520 kg / 3,351 lb | 28.1 kW, 135 A @ 208 V |
| Absen A3 Pro | 3.9 mm | 76 x 2 = 152 | 38 x 1 m | 9728 x 256 | 1,444 kg / 3,183 lb | 24.3 kW, 117 A @ 208 V |
Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.
Planning notes
No rigging point data is published for this venue yet; plan on ground-supported LED or ask the venue for its rigging plot. 11 of the 11 rooms sit under 3.5 m, which rules out flown LED there and limits ground-stacked walls to about 6 rows of 500 mm tile.
Data source
Published dimensions. Dimensions from the venue's published meeting-space specifications (source). Rooms drawn as boxes use published length x width; square rooms were derived from published area only, so treat their shape as approximate. Venue managers: send a floor plan to upgrade your listing to production-ready.