St George's Centre
St George's Centre in Leeds lists 8 event spaces totaling 827 m² (8,902 sq ft). The largest is The Hemming Suite at 17 x 17 m (56 x 56 ft) with a 3.1 m (10 ft) ceiling. The tallest ceiling on the property is 3.1 m (10 ft).
Open The Hemming Suite in 3D previzRooms
| Room | Floor | L x W (m) | L x W (ft) | Area | Ceiling | Rig pts | Data |
|---|---|---|---|---|---|---|---|
| The Hemming Suite | 17 x 17 | 56 x 56 | 289 m² / 3,111 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Function Room | 14.4 x 14.4 | 47 x 47 | 207 m² / 2,232 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Room 4 | 9.3 x 9.3 | 31 x 31 | 87 m² / 931 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Conservatory Room | 8.8 x 8.8 | 29 x 29 | 77 m² / 833 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Boardroom | 7.7 x 7.7 | 25 x 25 | 59 m² / 638 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Room 1 | 6.9 x 6.9 | 23 x 23 | 48 m² / 512 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Room 2 | 5.9 x 5.9 | 19 x 19 | 35 m² / 375 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Room 3 | 5 x 5 | 16 x 16 | 25 m² / 269 sq ft | 3.1 m / 10 ft | Published dimensions |
What fits in The Hemming Suite
With a 3.1 m ceiling, a flown wall of Absen A2 Pro (2.97 mm) runs 27 tiles wide by 2 high (54 tiles, 13.5 x 1 m, 4536 x 336 px) once you keep 1.5 m of trim under the bottom edge. That wall weighs about 540 kg and draws up to 10 kW (48 A at 208 V). Floor space after a 12 x 7 m stage seats roughly 455 theater, 186 banquet, or 128 classroom. The previz lets you move the wall, change the tile, and check sightlines from the back row.
| Panel | Pitch | Wall (cols x rows) | Size | Resolution | Weight | Power (max) |
|---|---|---|---|---|---|---|
| 9thPanel DW1.9 S Pro | 1.875 mm | 22 x 3 = 66 | 13.2 x 1 m | 7040 x 540 | 317 kg / 698 lb | 16.8 kW, 81 A @ 208 V |
| Absen A2 Pro | 2.97 mm | 27 x 2 = 54 | 13.5 x 1 m | 4536 x 336 | 540 kg / 1,190 lb | 10 kW, 48 A @ 208 V |
| Absen A3 Pro | 3.9 mm | 27 x 2 = 54 | 13.5 x 1 m | 3456 x 256 | 513 kg / 1,131 lb | 8.6 kW, 42 A @ 208 V |
Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.
Planning notes
No rigging point data is published for this venue yet; plan on ground-supported LED or ask the venue for its rigging plot. 8 of the 8 rooms sit under 3.5 m, which rules out flown LED there and limits ground-stacked walls to about 6 rows of 500 mm tile.
Data source
Published dimensions. Dimensions from the venue's published meeting-space specifications (source). Rooms drawn as boxes use published length x width; square rooms were derived from published area only, so treat their shape as approximate. Venue managers: send a floor plan to upgrade your listing to production-ready.