Mid Valley Exhibition Centre (MVEC)
Mid Valley Exhibition Centre (MVEC) in Kuala Lumpur lists 4 event spaces totaling 4,714 m² (50,737 sq ft). The largest is Hall 1 at 49.8 x 33 m (163 x 108 ft) with a 7.1 m (23 ft) ceiling. The tallest ceiling on the property is 7.1 m (23 ft).
Open Hall 1 in 3D previzRooms
| Room | Floor | L x W (m) | L x W (ft) | Area | Ceiling | Rig pts | Data |
|---|---|---|---|---|---|---|---|
| Hall 1 | 49.8 x 33 | 163 x 108 | 1,643 m² / 17,689 sq ft | 7.1 m / 23 ft | Published dimensions | ||
| Hall 2 | 47.5 x 33.3 | 156 x 109 | 1,582 m² / 17,025 sq ft | 7.1 m / 23 ft | Published dimensions | ||
| Hall 3 | 50.4 x 24.5 | 165 x 80 | 1,235 m² / 13,291 sq ft | 7.1 m / 23 ft | Published dimensions | ||
| Foyer Hall 3 | 15.1 x 16.8 | 50 x 55 | 254 m² / 2,731 sq ft | 7.1 m / 23 ft | Published dimensions |
What fits in Hall 1
With a 7.1 m ceiling, a flown wall of Absen A2 Pro (2.97 mm) runs 79 tiles wide by 10 high (790 tiles, 39.5 x 5 m, 13272 x 1680 px) once you keep 1.5 m of trim under the bottom edge. That wall weighs about 7,900 kg and draws up to 146.2 kW (703 A at 208 V). Floor space after a 12 x 7 m stage seats roughly 3,465 theater, 1,417 banquet, or 974 classroom. The previz lets you move the wall, change the tile, and check sightlines from the back row.
| Panel | Pitch | Wall (cols x rows) | Size | Resolution | Weight | Power (max) |
|---|---|---|---|---|---|---|
| 9thPanel DW1.9 S Pro | 1.875 mm | 66 x 15 = 990 | 39.6 x 5.1 m | 21120 x 2700 | 4,752 kg / 10,476 lb | 251.5 kW, 1209 A @ 208 V |
| Absen A2 Pro | 2.97 mm | 79 x 10 = 790 | 39.5 x 5 m | 13272 x 1680 | 7,900 kg / 17,416 lb | 146.2 kW, 703 A @ 208 V |
| Absen A3 Pro | 3.9 mm | 79 x 10 = 790 | 39.5 x 5 m | 10112 x 1280 | 7,505 kg / 16,546 lb | 126.4 kW, 608 A @ 208 V |
Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.
Planning notes
No rigging point data is published for this venue yet; plan on ground-supported LED or ask the venue for its rigging plot. Every room here clears 3.5 m, so ground-stacked LED works throughout.
Data source
Published dimensions. Dimensions from the venue's published meeting-space specifications (source). Rooms drawn as boxes use published length x width; shapes are as published. Venue managers: send a floor plan to upgrade your listing to production-ready.