Published dimensions

Meeting Room 402 is 11 x 8.2 m (36 x 27 ft), 90 m² (971 sq ft), with a 3.5 m (11 ft) ceiling.

Open in 3D previz

Plan view

11 m / 36 ft8.2 m / 27 ft grid 1 m

LED wall that fits

Under a 3.5 m ceiling with 1.5 m trim and 0.3 m clearance you get 3 rows of 500 mm tile flown, which is tight; ground-stack or go lower on trim. Along the 11 m wall a Absen A2 Pro wall runs 17 x 3 (2856 x 504 px, 510 kg, 9.4 kW).

PanelPitchWall (cols x rows)SizeResolutionWeightPower (max)
9thPanel DW1.9 S Pro1.875 mm14 x 5 = 708.4 x 1.7 m4480 x 900336 kg / 741 lb17.8 kW, 85 A @ 208 V
Absen A2 Pro2.97 mm17 x 3 = 518.5 x 1.5 m2856 x 504510 kg / 1,124 lb9.4 kW, 45 A @ 208 V
Absen A3 Pro3.9 mm17 x 3 = 518.5 x 1.5 m2176 x 384485 kg / 1,068 lb8.2 kW, 39 A @ 208 V

Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.

Seating estimate

After a 12 x 7 m stage, Meeting Room 402 holds about 13 theater seats, 5 banquet seats at rounds of 10, or 3 classroom seats. Back row in theater is roughly 4 m from the downstage edge; the previz checks whether the bottom of the wall clears the heads in front.