Ice Krakow Congress Centre
Ice Krakow Congress Centre in Krakow lists 5 event spaces totaling 5,223 m² (56,220 sq ft). The largest is Foyer at 54.8 x 54.8 m (180 x 180 ft) with a 3.9 m (13 ft) ceiling. The tallest ceiling on the property is 16 m (52 ft).
Open Foyer in 3D previzRooms
| Room | Floor | L x W (m) | L x W (ft) | Area | Ceiling | Rig pts | Data |
|---|---|---|---|---|---|---|---|
| Foyer | 54.8 x 54.8 | 180 x 180 | 3,003 m² / 32,324 sq ft | 3.9 m / 13 ft | Published dimensions | ||
| Theatre Hall | 33 x 20 | 108 x 66 | 660 m² / 7,104 sq ft | 10.8 m / 35 ft | Published dimensions | ||
| Auditorium Hall | 28 x 20 | 92 x 66 | 560 m² / 6,028 sq ft | 16 m / 52 ft | Published dimensions | ||
| Chamber Hall | 25 x 20 | 82 x 66 | 500 m² / 5,382 sq ft | 3.9 m / 13 ft | Published dimensions | ||
| Conference Hall Complex | 25 x 20 | 82 x 66 | 500 m² / 5,382 sq ft | 3.9 m / 13 ft | Published dimensions |
What fits in Foyer
With a 3.9 m ceiling, a flown wall of Absen A2 Pro (2.97 mm) runs 87 tiles wide by 4 high (348 tiles, 43.5 x 2 m, 14616 x 672 px) once you keep 1.5 m of trim under the bottom edge. That wall weighs about 3,480 kg and draws up to 64.4 kW (310 A at 208 V). Floor space after a 12 x 7 m stage seats roughly 6,486 theater, 2,653 banquet, or 1,824 classroom. The previz lets you move the wall, change the tile, and check sightlines from the back row.
| Panel | Pitch | Wall (cols x rows) | Size | Resolution | Weight | Power (max) |
|---|---|---|---|---|---|---|
| 9thPanel DW1.9 S Pro | 1.875 mm | 73 x 6 = 438 | 43.8 x 2 m | 23360 x 1080 | 2,102 kg / 4,635 lb | 111.3 kW, 535 A @ 208 V |
| Absen A2 Pro | 2.97 mm | 87 x 4 = 348 | 43.5 x 2 m | 14616 x 672 | 3,480 kg / 7,672 lb | 64.4 kW, 310 A @ 208 V |
| Absen A3 Pro | 3.9 mm | 87 x 4 = 348 | 43.5 x 2 m | 11136 x 512 | 3,306 kg / 7,288 lb | 55.7 kW, 268 A @ 208 V |
Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.
Planning notes
No rigging point data is published for this venue yet; plan on ground-supported LED or ask the venue for its rigging plot. Every room here clears 3.5 m, so ground-stacked LED works throughout.
Data source
Published dimensions. Dimensions from the venue's published meeting-space specifications (source). Rooms drawn as boxes use published length x width; square rooms were derived from published area only, so treat their shape as approximate. Venue managers: send a floor plan to upgrade your listing to production-ready.