Meeting Room 301 A-C at Knoxville Convention Center

Published dimensions

Meeting Room 301 A-C is 20.7 x 20.7 m (68 x 68 ft), 429 m² (4,612 sq ft), with a 4.9 m (16 ft) ceiling.

Open in 3D previz

Plan view

20.7 m / 68 ft20.7 m / 68 ft grid 1 m

Shape approximate: the venue publishes area only, so this room is drawn as a square of equal area.

LED wall that fits

Under a 4.9 m ceiling with 1.5 m trim and 0.3 m clearance you get 6 rows of 500 mm tile flown. Along the 20.7 m wall a Absen A2 Pro wall runs 33 x 6 (5544 x 1008 px, 1,980 kg, 36.6 kW).

PanelPitchWall (cols x rows)SizeResolutionWeightPower (max)
9thPanel DW1.9 S Pro1.875 mm27 x 9 = 24316.2 x 3 m8640 x 16201,166 kg / 2,571 lb61.7 kW, 297 A @ 208 V
Absen A2 Pro2.97 mm33 x 6 = 19816.5 x 3 m5544 x 10081,980 kg / 4,365 lb36.6 kW, 176 A @ 208 V
Absen A3 Pro3.9 mm33 x 6 = 19816.5 x 3 m4224 x 7681,881 kg / 4,147 lb31.7 kW, 152 A @ 208 V

Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.

Seating estimate

After a 12 x 7 m stage, Meeting Room 301 A-C holds about 765 theater seats, 313 banquet seats at rounds of 10, or 215 classroom seats. Back row in theater is roughly 13.7 m from the downstage edge; the previz checks whether the bottom of the wall clears the heads in front.