Klagenfurter Messe
Klagenfurter Messe in Klagenfurt lists 7 event spaces totaling 27,047 m² (291,132 sq ft). The largest is Hall 3 at 80 x 80 m (262 x 262 ft) with a 3.1 m (10 ft) ceiling. The tallest ceiling on the property is 3.1 m (10 ft).
Open Hall 3 in 3D previzRooms
| Room | Floor | L x W (m) | L x W (ft) | Area | Ceiling | Rig pts | Data |
|---|---|---|---|---|---|---|---|
| Hall 3 | 80 x 80 | 262 x 262 | 6,400 m² / 68,889 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Hall 5 | 77.5 x 77.5 | 254 x 254 | 6,006 m² / 64,651 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Hall 1 | 66.4 x 66.4 | 218 x 218 | 4,409 m² / 47,458 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Hall 6 | 64.8 x 64.8 | 213 x 213 | 4,199 m² / 45,198 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Hall 7 | 56.6 x 56.6 | 186 x 186 | 3,204 m² / 34,483 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Hall 2 | 38.5 x 38.5 | 126 x 126 | 1,482 m² / 15,955 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Upper floor | 36.7 x 36.7 | 120 x 120 | 1,347 m² / 14,498 sq ft | 3.1 m / 10 ft | Published dimensions |
What fits in Hall 3
With a 3.1 m ceiling, a flown wall of Absen A2 Pro (2.97 mm) runs 128 tiles wide by 2 high (256 tiles, 64 x 1 m, 21504 x 336 px) once you keep 1.5 m of trim under the bottom edge. That wall weighs about 2,560 kg and draws up to 47.4 kW (228 A at 208 V). Floor space after a 12 x 7 m stage seats roughly 14,035 theater, 5,741 banquet, or 3,947 classroom. The previz lets you move the wall, change the tile, and check sightlines from the back row.
| Panel | Pitch | Wall (cols x rows) | Size | Resolution | Weight | Power (max) |
|---|---|---|---|---|---|---|
| 9thPanel DW1.9 S Pro | 1.875 mm | 106 x 3 = 318 | 63.6 x 1 m | 33920 x 540 | 1,526 kg / 3,365 lb | 80.8 kW, 388 A @ 208 V |
| Absen A2 Pro | 2.97 mm | 128 x 2 = 256 | 64 x 1 m | 21504 x 336 | 2,560 kg / 5,644 lb | 47.4 kW, 228 A @ 208 V |
| Absen A3 Pro | 3.9 mm | 128 x 2 = 256 | 64 x 1 m | 16384 x 256 | 2,432 kg / 5,362 lb | 41 kW, 197 A @ 208 V |
Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.
Planning notes
No rigging point data is published for this venue yet; plan on ground-supported LED or ask the venue for its rigging plot. 7 of the 7 rooms sit under 3.5 m, which rules out flown LED there and limits ground-stacked walls to about 6 rows of 500 mm tile.
Data source
Published dimensions. Dimensions from the venue's published meeting-space specifications (source). Rooms drawn as boxes use published length x width; square rooms were derived from published area only, so treat their shape as approximate. Venue managers: send a floor plan to upgrade your listing to production-ready.