Published dimensionsKansas City

T-Mobile Center in Kansas City lists 8 event spaces totaling 5,641 m² (60,715 sq ft). The largest is Arena at 25.9 x 71.6 m (85 x 235 ft) with a 23.2 m (76 ft) ceiling. The tallest ceiling on the property is 23.2 m (76 ft).

Open Arena in 3D previz

Rooms

RoomFloorL x W (m)L x W (ft)AreaCeilingRig ptsData
Arena25.9 x 71.685 x 2351,854 m² / 19,961 sq ft23.2 m / 76 ftPublished dimensions
South Concourse36.8 x 36.8121 x 1211,354 m² / 14,576 sq ft12.2 m / 40 ftPublished dimensions
Grand Lobby27.9 x 27.992 x 92778 m² / 8,379 sq ft12.2 m / 40 ftPublished dimensions
West Concourse26.1 x 26.186 x 86681 m² / 7,332 sq ft12.2 m / 40 ftPublished dimensions
Founders Club24.9 x 24.982 x 82620 m² / 6,674 sq ft3.7 m / 12 ftPublished dimensions
Event Center12 x 1239 x 39144 m² / 1,550 sq ft3 m / 10 ftPublished dimensions
Club Magenta10.6 x 10.635 x 35112 m² / 1,210 sq ft3.7 m / 12 ftPublished dimensions
Grand Boulevard Conference Room9.8 x 9.832 x 3296 m² / 1,033 sq ft3 m / 10 ftPublished dimensions

What fits in Arena

With a 23.2 m ceiling, a flown wall of Absen A2 Pro (2.97 mm) runs 114 tiles wide by 42 high (4788 tiles, 57 x 21 m, 19152 x 7056 px) once you keep 1.5 m of trim under the bottom edge. That wall weighs about 47,880 kg and draws up to 885.8 kW (4259 A at 208 V). Floor space after a 12 x 7 m stage seats roughly 3,934 theater, 1,609 banquet, or 1,106 classroom. The previz lets you move the wall, change the tile, and check sightlines from the back row.

PanelPitchWall (cols x rows)SizeResolutionWeightPower (max)
9thPanel DW1.9 S Pro1.875 mm95 x 63 = 598557 x 21.3 m30400 x 1134028,728 kg / 63,334 lb1520.2 kW, 7309 A @ 208 V
Absen A2 Pro2.97 mm114 x 42 = 478857 x 21 m19152 x 705647,880 kg / 105,556 lb885.8 kW, 4259 A @ 208 V
Absen A3 Pro3.9 mm114 x 42 = 478857 x 21 m14592 x 537645,486 kg / 100,278 lb766.1 kW, 3683 A @ 208 V

Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.

Planning notes

No rigging point data is published for this venue yet; plan on ground-supported LED or ask the venue for its rigging plot. 2 of the 8 rooms sit under 3.5 m, which rules out flown LED there and limits ground-stacked walls to about 6 rows of 500 mm tile.

Data source

Published dimensions. Dimensions from the venue's published meeting-space specifications (source). Rooms drawn as boxes use published length x width; square rooms were derived from published area only, so treat their shape as approximate. Venue managers: send a floor plan to upgrade your listing to production-ready.

More venues in Kansas City · All venues