Arrowhead Stadium
Arrowhead Stadium in Kansas City lists 13 event spaces totaling 6,963 m² (74,944 sq ft). The largest is North Club at 41.9 x 41.9 m (137 x 137 ft) with a 3.1 m (10 ft) ceiling. The tallest ceiling on the property is 3.1 m (10 ft).
Open North Club in 3D previzRooms
| Room | Floor | L x W (m) | L x W (ft) | Area | Ceiling | Rig pts | Data |
|---|---|---|---|---|---|---|---|
| North Club | 41.9 x 41.9 | 137 x 137 | 1,756 m² / 18,897 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Tower Club East | 34.1 x 34.1 | 112 x 112 | 1,163 m² / 12,516 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Founder's Club | 32.1 x 32.1 | 105 x 105 | 1,030 m² / 11,091 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Tower Club West | 30.2 x 30.2 | 99 x 99 | 912 m² / 9,817 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Foolish Club | 25.4 x 25.4 | 83 x 83 | 645 m² / 6,945 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Broadcast Suite Lounge | 22.7 x 22.7 | 74 x 74 | 515 m² / 5,547 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Club IV | 22.5 x 22.5 | 74 x 74 | 506 m² / 5,450 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Press Box Lounge | 18.5 x 18.5 | 61 x 61 | 342 m² / 3,684 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Penthouse | 9.6 x 9.6 | 31 x 31 | 92 m² / 992 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Kingdom Club | 0.3 x 0.3 | 1 x 1 | 0 m² / 1 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Locker Room Club | 0.3 x 0.3 | 1 x 1 | 0 m² / 1 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Press Conference Auditorium | 0.3 x 0.3 | 1 x 1 | 0 m² / 1 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Signature Suite Lounge | 0.3 x 0.3 | 1 x 1 | 0 m² / 1 sq ft | 3.1 m / 10 ft | Published dimensions |
What fits in North Club
With a 3.1 m ceiling, a flown wall of Absen A2 Pro (2.97 mm) runs 67 tiles wide by 2 high (134 tiles, 33.5 x 1 m, 11256 x 336 px) once you keep 1.5 m of trim under the bottom edge. That wall weighs about 1,340 kg and draws up to 24.8 kW (119 A at 208 V). Floor space after a 12 x 7 m stage seats roughly 3,714 theater, 1,519 banquet, or 1,044 classroom. The previz lets you move the wall, change the tile, and check sightlines from the back row.
| Panel | Pitch | Wall (cols x rows) | Size | Resolution | Weight | Power (max) |
|---|---|---|---|---|---|---|
| 9thPanel DW1.9 S Pro | 1.875 mm | 55 x 3 = 165 | 33 x 1 m | 17600 x 540 | 792 kg / 1,746 lb | 41.9 kW, 201 A @ 208 V |
| Absen A2 Pro | 2.97 mm | 67 x 2 = 134 | 33.5 x 1 m | 11256 x 336 | 1,340 kg / 2,954 lb | 24.8 kW, 119 A @ 208 V |
| Absen A3 Pro | 3.9 mm | 67 x 2 = 134 | 33.5 x 1 m | 8576 x 256 | 1,273 kg / 2,806 lb | 21.4 kW, 103 A @ 208 V |
Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.
Planning notes
No rigging point data is published for this venue yet; plan on ground-supported LED or ask the venue for its rigging plot. 13 of the 13 rooms sit under 3.5 m, which rules out flown LED there and limits ground-stacked walls to about 6 rows of 500 mm tile.
Data source
Published dimensions. Dimensions from the venue's published meeting-space specifications (source). Rooms drawn as boxes use published length x width; square rooms were derived from published area only, so treat their shape as approximate. Venue managers: send a floor plan to upgrade your listing to production-ready.