TKP Garden City Premium Yokohama Station Shin-Takashima
TKP Garden City Premium Yokohama Station Shin-Takashima in Kanagawa lists 6 event spaces totaling 682 m² (7,340 sq ft). The largest is Hall 2C at 14.5 x 14.5 m (48 x 48 ft) with a 3.5 m (11 ft) ceiling. The tallest ceiling on the property is 3.5 m (11 ft).
Open Hall 2C in 3D previzRooms
| Room | Floor | L x W (m) | L x W (ft) | Area | Ceiling | Rig pts | Data |
|---|---|---|---|---|---|---|---|
| Hall 2C | 14.5 x 14.5 | 48 x 48 | 210 m² / 2,264 sq ft | 3.5 m / 11 ft | Published dimensions | ||
| Hall 2B | 14.2 x 14.2 | 47 x 47 | 202 m² / 2,170 sq ft | 3.5 m / 11 ft | Published dimensions | ||
| Conference room 2D | 10.6 x 10.6 | 35 x 35 | 112 m² / 1,210 sq ft | 3.5 m / 11 ft | Published dimensions | ||
| Conference room 2E | 10.6 x 10.6 | 35 x 35 | 112 m² / 1,210 sq ft | 3.5 m / 11 ft | Published dimensions | ||
| Meeting room 2G | 4.9 x 4.9 | 16 x 16 | 24 m² / 258 sq ft | 3.5 m / 11 ft | Published dimensions | ||
| Meeting room 2F | 4.6 x 4.6 | 15 x 15 | 21 m² / 228 sq ft | 3.5 m / 11 ft | Published dimensions |
What fits in Hall 2C
With a 3.5 m ceiling, a flown wall of Absen A2 Pro (2.97 mm) runs 23 tiles wide by 3 high (69 tiles, 11.5 x 1.5 m, 3864 x 504 px) once you keep 1.5 m of trim under the bottom edge. That wall weighs about 690 kg and draws up to 12.8 kW (61 A at 208 V). Floor space after a 12 x 7 m stage seats roughly 280 theater, 114 banquet, or 78 classroom. The previz lets you move the wall, change the tile, and check sightlines from the back row.
| Panel | Pitch | Wall (cols x rows) | Size | Resolution | Weight | Power (max) |
|---|---|---|---|---|---|---|
| 9thPanel DW1.9 S Pro | 1.875 mm | 19 x 5 = 95 | 11.4 x 1.7 m | 6080 x 900 | 456 kg / 1,005 lb | 24.1 kW, 116 A @ 208 V |
| Absen A2 Pro | 2.97 mm | 23 x 3 = 69 | 11.5 x 1.5 m | 3864 x 504 | 690 kg / 1,521 lb | 12.8 kW, 61 A @ 208 V |
| Absen A3 Pro | 3.9 mm | 23 x 3 = 69 | 11.5 x 1.5 m | 2944 x 384 | 656 kg / 1,445 lb | 11 kW, 53 A @ 208 V |
Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.
Planning notes
No rigging point data is published for this venue yet; plan on ground-supported LED or ask the venue for its rigging plot. Every room here clears 3.5 m, so ground-stacked LED works throughout.
Data source
Published dimensions. Dimensions from the venue's published meeting-space specifications (source). Rooms drawn as boxes use published length x width; square rooms were derived from published area only, so treat their shape as approximate. Venue managers: send a floor plan to upgrade your listing to production-ready.