1st Floor (Stampede) at Imagen Venues Stampede Event Center
1st Floor (Stampede) is 61 x 60 m (200 x 197 ft), 3,660 m² (39,396 sq ft), with a 3.1 m (10 ft) ceiling.
Open in 3D previzPlan view
LED wall that fits
Under a 3.1 m ceiling with 1.5 m trim and 0.3 m clearance you get 2 rows of 500 mm tile flown, which is tight; ground-stack or go lower on trim. Along the 61 m wall a Absen A2 Pro wall runs 97 x 2 (16296 x 336 px, 1,940 kg, 35.9 kW).
| Panel | Pitch | Wall (cols x rows) | Size | Resolution | Weight | Power (max) |
|---|---|---|---|---|---|---|
| 9thPanel DW1.9 S Pro | 1.875 mm | 81 x 3 = 243 | 48.6 x 1 m | 25920 x 540 | 1,166 kg / 2,571 lb | 61.7 kW, 297 A @ 208 V |
| Absen A2 Pro | 2.97 mm | 97 x 2 = 194 | 48.5 x 1 m | 16296 x 336 | 1,940 kg / 4,277 lb | 35.9 kW, 173 A @ 208 V |
| Absen A3 Pro | 3.9 mm | 97 x 2 = 194 | 48.5 x 1 m | 12416 x 256 | 1,843 kg / 4,063 lb | 31 kW, 149 A @ 208 V |
Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.
Seating estimate
After a 12 x 7 m stage, 1st Floor (Stampede) holds about 7,946 theater seats, 3,250 banquet seats at rounds of 10, or 2,235 classroom seats. Back row in theater is roughly 54 m from the downstage edge; the previz checks whether the bottom of the wall clears the heads in front.
Other rooms at Imagen Venues Stampede Event Center
- 2nd Fl (Stampede)47.3 x 47.3 m (155 x 155 ft) · 3.1 m ceiling
- Lonestar Room15.8 x 15.8 m (52 x 52 ft) · 3.1 m ceiling
Published dimensions (source), fetched 2026-09-05. All rooms at Imagen Venues Stampede Event Center · Venues in Houston