Imagen Venues Escapade Event Center
Imagen Venues Escapade Event Center in Houston lists 6 event spaces totaling 6,391 m² (68,793 sq ft). The largest is 2nd Floor (Escapade) at 55.1 x 55.1 m (181 x 181 ft) with a 3.1 m (10 ft) ceiling. The tallest ceiling on the property is 3.1 m (10 ft).
Open 2nd Floor (Escapade) in 3D previzRooms
| Room | Floor | L x W (m) | L x W (ft) | Area | Ceiling | Rig pts | Data |
|---|---|---|---|---|---|---|---|
| 2nd Floor (Escapade) | 55.1 x 55.1 | 181 x 181 | 3,036 m² / 32,679 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| 1st Floor (Escapade) | 52.1 x 45.7 | 171 x 150 | 2,381 m² / 25,629 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| North Banquet Room | 20.4 x 20.4 | 67 x 67 | 416 m² / 4,480 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| East Banquet Room | 16.7 x 16.7 | 55 x 55 | 279 m² / 3,002 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| West Banquet Room | 16.7 x 16.7 | 55 x 55 | 279 m² / 3,002 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Conference Center | 0.3 x 0.3 | 1 x 1 | 0 m² / 1 sq ft | 3.1 m / 10 ft | Published dimensions |
What fits in 2nd Floor (Escapade)
With a 3.1 m ceiling, a flown wall of Absen A2 Pro (2.97 mm) runs 88 tiles wide by 2 high (176 tiles, 44 x 1 m, 14784 x 336 px) once you keep 1.5 m of trim under the bottom edge. That wall weighs about 1,760 kg and draws up to 32.6 kW (157 A at 208 V). Floor space after a 12 x 7 m stage seats roughly 6,560 theater, 2,683 banquet, or 1,845 classroom. The previz lets you move the wall, change the tile, and check sightlines from the back row.
| Panel | Pitch | Wall (cols x rows) | Size | Resolution | Weight | Power (max) |
|---|---|---|---|---|---|---|
| 9thPanel DW1.9 S Pro | 1.875 mm | 73 x 3 = 219 | 43.8 x 1 m | 23360 x 540 | 1,051 kg / 2,317 lb | 55.6 kW, 267 A @ 208 V |
| Absen A2 Pro | 2.97 mm | 88 x 2 = 176 | 44 x 1 m | 14784 x 336 | 1,760 kg / 3,880 lb | 32.6 kW, 157 A @ 208 V |
| Absen A3 Pro | 3.9 mm | 88 x 2 = 176 | 44 x 1 m | 11264 x 256 | 1,672 kg / 3,686 lb | 28.2 kW, 135 A @ 208 V |
Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.
Planning notes
No rigging point data is published for this venue yet; plan on ground-supported LED or ask the venue for its rigging plot. 6 of the 6 rooms sit under 3.5 m, which rules out flown LED there and limits ground-stacked walls to about 6 rows of 500 mm tile.
Data source
Published dimensions. Dimensions from the venue's published meeting-space specifications (source). Rooms drawn as boxes use published length x width; square rooms were derived from published area only, so treat their shape as approximate. Venue managers: send a floor plan to upgrade your listing to production-ready.