Tanner Preserve AV
Home / Venues / George R. Brown Convention Center / Meeting Room 382

Meeting Room 382 at George R. Brown Convention Center

Published dimensions

Meeting Room 382 is 12.8 x 32.6 m (42 x 107 ft), 417 m² (4,492 sq ft), with a 6.4 m (21 ft) ceiling.

Open in 3D previz

Plan view

12.8 m / 42 ft32.6 m / 107 ft grid 5 m

LED wall that fits

Under a 6.4 m ceiling with 1.5 m trim and 0.3 m clearance you get 9 rows of 500 mm tile flown. Along the 32.6 m wall a Absen A2 Pro wall runs 52 x 9 (8736 x 1512 px, 4,680 kg, 86.6 kW).

PanelPitchWall (cols x rows)SizeResolutionWeightPower (max)
9thPanel DW1.9 S Pro1.875 mm43 x 13 = 55925.8 x 4.4 m13760 x 23402,683 kg / 5,915 lb142 kW, 683 A @ 208 V
Absen A2 Pro2.97 mm52 x 9 = 46826 x 4.5 m8736 x 15124,680 kg / 10,318 lb86.6 kW, 416 A @ 208 V
Absen A3 Pro3.9 mm52 x 9 = 46826 x 4.5 m6656 x 11524,446 kg / 9,802 lb74.9 kW, 360 A @ 208 V

Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.

Seating estimate

After a 12 x 7 m stage, Meeting Room 382 holds about 740 theater seats, 303 banquet seats at rounds of 10, or 208 classroom seats. Back row in theater is roughly 25.6 m from the downstage edge; the previz checks whether the bottom of the wall clears the heads in front.

Other rooms at George R. Brown Convention Center

Published dimensions (source), fetched 2026-09-04. All rooms at George R. Brown Convention Center · Venues in Houston