Section ABC at G&L Event Center
Section ABC is 33.8 x 18.3 m (111 x 60 ft), 619 m² (6,657 sq ft), with a 4.6 m (15 ft) ceiling.
Open in 3D previzPlan view
LED wall that fits
Under a 4.6 m ceiling with 1.5 m trim and 0.3 m clearance you get 5 rows of 500 mm tile flown. Along the 33.8 m wall a Absen A2 Pro wall runs 54 x 5 (9072 x 840 px, 2,700 kg, 50 kW).
| Panel | Pitch | Wall (cols x rows) | Size | Resolution | Weight | Power (max) |
|---|---|---|---|---|---|---|
| 9thPanel DW1.9 S Pro | 1.875 mm | 45 x 8 = 360 | 27 x 2.7 m | 14400 x 1440 | 1,728 kg / 3,810 lb | 91.4 kW, 440 A @ 208 V |
| Absen A2 Pro | 2.97 mm | 54 x 5 = 270 | 27 x 2.5 m | 9072 x 840 | 2,700 kg / 5,952 lb | 50 kW, 240 A @ 208 V |
| Absen A3 Pro | 3.9 mm | 54 x 5 = 270 | 27 x 2.5 m | 6912 x 640 | 2,565 kg / 5,655 lb | 43.2 kW, 208 A @ 208 V |
Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.
Seating estimate
After a 12 x 7 m stage, Section ABC holds about 1,187 theater seats, 485 banquet seats at rounds of 10, or 334 classroom seats. Back row in theater is roughly 26.8 m from the downstage edge; the previz checks whether the bottom of the wall clears the heads in front.
Other rooms at G&L Event Center
- Section C20.4 x 18.3 m (67 x 60 ft) · 4.6 m ceiling
- Section A9.1 x 13.4 m (30 x 44 ft) · 4.6 m ceiling
- Section B9.1 x 13.4 m (30 x 44 ft) · 4.6 m ceiling
Published dimensions (source), fetched 2026-09-05. All rooms at G&L Event Center · Venues in Houston