Hickory Metro Convention Center and Visitors Bureau
Hickory Metro Convention Center and Visitors Bureau in Hickory lists 24 event spaces totaling 16,258 m² (174,998 sq ft). The largest is Hickory 1-4 at 48.8 x 73.8 m (160 x 242 ft) with a 4.9 m (16 ft) ceiling. The tallest ceiling on the property is 5.5 m (18 ft).
Open Hickory 1-4 in 3D previzRooms
| Room | Floor | L x W (m) | L x W (ft) | Area | Ceiling | Rig pts | Data |
|---|---|---|---|---|---|---|---|
| Hickory 1-4 | 48.8 x 73.8 | 160 x 242 | 3,601 m² / 38,765 sq ft | 4.9 m / 16 ft | Published dimensions | ||
| Catawba 1 - 6 | 64 x 36.6 | 210 x 120 | 2,342 m² / 25,213 sq ft | 4.9 m / 16 ft | Published dimensions | ||
| Hickory 1 | 48.8 x 24.4 | 160 x 80 | 1,191 m² / 12,817 sq ft | 4.9 m / 16 ft | Published dimensions | ||
| Hickory 2 | 48.8 x 24.4 | 160 x 80 | 1,191 m² / 12,817 sq ft | 4.9 m / 16 ft | Published dimensions | ||
| Catawba 5 & 6 | 36.6 x 24.4 | 120 x 80 | 893 m² / 9,612 sq ft | 4.9 m / 16 ft | Published dimensions | ||
| Catawba 3 & 4 | 36.6 x 21.3 | 120 x 70 | 780 m² / 8,392 sq ft | 4.9 m / 16 ft | Published dimensions | ||
| Catawba 1 & 2 | 36.6 x 18.3 | 120 x 60 | 670 m² / 7,210 sq ft | 4.9 m / 16 ft | Published dimensions | ||
| Hickory 3 | 24.4 x 25 | 80 x 82 | 610 m² / 6,566 sq ft | 4.9 m / 16 ft | Published dimensions | ||
| Hickory 4 | 24.4 x 25 | 80 x 82 | 610 m² / 6,566 sq ft | 4.9 m / 16 ft | Published dimensions | ||
| Conover 1-4 | 42.7 x 13.4 | 140 x 44 | 572 m² / 6,159 sq ft | 3.7 m / 12 ft | Published dimensions | ||
| Hallways | 51.8 x 9.1 | 170 x 30 | 471 m² / 5,074 sq ft | 5.5 m / 18 ft | Published dimensions | ||
| Hickory Junction | 17.7 x 25.3 | 58 x 83 | 448 m² / 4,820 sq ft | 3.7 m / 12 ft | Published dimensions | ||
| Catawba 6 | 24.4 x 18.3 | 80 x 60 | 447 m² / 4,806 sq ft | 4.9 m / 16 ft | Published dimensions | ||
| Catawba 4 | 21.3 x 18.3 | 70 x 60 | 390 m² / 4,196 sq ft | 4.9 m / 16 ft | Published dimensions | ||
| Catawba 2 | 18.3 x 18.3 | 60 x 60 | 335 m² / 3,605 sq ft | 4.9 m / 16 ft | Published dimensions | ||
| Catawba 5 | 24.4 x 12.2 | 80 x 40 | 298 m² / 3,204 sq ft | 4.9 m / 16 ft | Published dimensions | ||
| Vestibule | 31.1 x 9.1 | 102 x 30 | 283 m² / 3,046 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Catawba 1 | 21.3 x 12.2 | 70 x 40 | 260 m² / 2,798 sq ft | 4.9 m / 16 ft | Published dimensions | ||
| Catawba 3 | 21.3 x 12.2 | 70 x 40 | 260 m² / 2,798 sq ft | 4.9 m / 16 ft | Published dimensions | ||
| Conover 1 | 10.7 x 13.4 | 35 x 44 | 143 m² / 1,544 sq ft | 3.7 m / 12 ft | Published dimensions | ||
| Conover 2 | 10.7 x 13.4 | 35 x 44 | 143 m² / 1,544 sq ft | 3.7 m / 12 ft | Published dimensions | ||
| Conover 3 | 10.7 x 13.4 | 35 x 44 | 143 m² / 1,544 sq ft | 3.7 m / 12 ft | Published dimensions | ||
| Conover 4 | 10.7 x 13.4 | 35 x 44 | 143 m² / 1,544 sq ft | 3.7 m / 12 ft | Published dimensions | ||
| Boardroom | 6.1 x 5.5 | 20 x 18 | 34 m² / 362 sq ft | 3.7 m / 12 ft | Published dimensions |
What fits in Hickory 1-4
With a 4.9 m ceiling, a flown wall of Absen A2 Pro (2.97 mm) runs 118 tiles wide by 6 high (708 tiles, 59 x 3 m, 19824 x 1008 px) once you keep 1.5 m of trim under the bottom edge. That wall weighs about 7,080 kg and draws up to 131 kW (630 A at 208 V). Floor space after a 12 x 7 m stage seats roughly 7,816 theater, 3,197 banquet, or 2,198 classroom. The previz lets you move the wall, change the tile, and check sightlines from the back row.
| Panel | Pitch | Wall (cols x rows) | Size | Resolution | Weight | Power (max) |
|---|---|---|---|---|---|---|
| 9thPanel DW1.9 S Pro | 1.875 mm | 98 x 9 = 882 | 58.8 x 3 m | 31360 x 1620 | 4,234 kg / 9,333 lb | 224 kW, 1077 A @ 208 V |
| Absen A2 Pro | 2.97 mm | 118 x 6 = 708 | 59 x 3 m | 19824 x 1008 | 7,080 kg / 15,609 lb | 131 kW, 630 A @ 208 V |
| Absen A3 Pro | 3.9 mm | 118 x 6 = 708 | 59 x 3 m | 15104 x 768 | 6,726 kg / 14,828 lb | 113.3 kW, 545 A @ 208 V |
Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.
Planning notes
No rigging point data is published for this venue yet; plan on ground-supported LED or ask the venue for its rigging plot. 1 of the 24 rooms sit under 3.5 m, which rules out flown LED there and limits ground-stacked walls to about 6 rows of 500 mm tile.
Data source
Published dimensions. Dimensions from the venue's published meeting-space specifications (source). Rooms drawn as boxes use published length x width; square rooms were derived from published area only, so treat their shape as approximate. Venue managers: send a floor plan to upgrade your listing to production-ready.