Tanner Preserve AV
Home / Venues / Grantham / Arena UK

Arena UK

Published dimensionsGrantham

Arena UK in Grantham lists 6 event spaces totaling 2,797 m² (30,112 sq ft). The largest is Marquee 2 at 30.8 x 30.8 m (101 x 101 ft) with a 3.1 m (10 ft) ceiling. The tallest ceiling on the property is 3.1 m (10 ft).

Open Marquee 2 in 3D previz

Rooms

RoomFloorL x W (m)L x W (ft)AreaCeilingRig ptsData
Marquee 230.8 x 30.8101 x 101949 m² / 10,211 sq ft3.1 m / 10 ftPublished dimensions
Marquee 330.8 x 30.8101 x 101949 m² / 10,211 sq ft3.1 m / 10 ftPublished dimensions
Marquee 130 x 3098 x 98900 m² / 9,688 sq ft3.1 m / 10 ftPublished dimensions
Bistro0.3 x 0.31 x 10 m² / 1 sq ft3.1 m / 10 ftPublished dimensions
Conservatory Bar0.3 x 0.31 x 10 m² / 1 sq ft3.1 m / 10 ftPublished dimensions
Restaurant0.3 x 0.31 x 10 m² / 1 sq ft3.1 m / 10 ftPublished dimensions

What fits in Marquee 2

With a 3.1 m ceiling, a flown wall of Absen A2 Pro (2.97 mm) runs 49 tiles wide by 2 high (98 tiles, 24.5 x 1 m, 8232 x 336 px) once you keep 1.5 m of trim under the bottom edge. That wall weighs about 980 kg and draws up to 18.1 kW (87 A at 208 V). Floor space after a 12 x 7 m stage seats roughly 1,921 theater, 786 banquet, or 540 classroom. The previz lets you move the wall, change the tile, and check sightlines from the back row.

PanelPitchWall (cols x rows)SizeResolutionWeightPower (max)
9thPanel DW1.9 S Pro1.875 mm41 x 3 = 12324.6 x 1 m13120 x 540590 kg / 1,302 lb31.2 kW, 150 A @ 208 V
Absen A2 Pro2.97 mm49 x 2 = 9824.5 x 1 m8232 x 336980 kg / 2,161 lb18.1 kW, 87 A @ 208 V
Absen A3 Pro3.9 mm49 x 2 = 9824.5 x 1 m6272 x 256931 kg / 2,052 lb15.7 kW, 75 A @ 208 V

Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.

Planning notes

No rigging point data is published for this venue yet; plan on ground-supported LED or ask the venue for its rigging plot. 6 of the 6 rooms sit under 3.5 m, which rules out flown LED there and limits ground-stacked walls to about 6 rows of 500 mm tile.

Data source

Published dimensions. Dimensions from the venue's published meeting-space specifications (source). Rooms drawn as boxes use published length x width; square rooms were derived from published area only, so treat their shape as approximate. Venue managers: send a floor plan to upgrade your listing to production-ready.

More venues in Grantham · All venues