Tanner Preserve AV
Home / Venues / Gothenburg / Lindholmen Conference Centre

Lindholmen Conference Centre

Published dimensionsGothenburg

Lindholmen Conference Centre in Gothenburg lists 8 event spaces totaling 805 m² (8,661 sq ft). The largest is Lindholmen Conference Hall at 21.2 x 21.2 m (70 x 70 ft) with a 3.1 m (10 ft) ceiling. The tallest ceiling on the property is 3.1 m (10 ft).

Open Lindholmen Conference Hall in 3D previz

Rooms

RoomFloorL x W (m)L x W (ft)AreaCeilingRig ptsData
Lindholmen Conference Hall21.2 x 21.270 x 70449 m² / 4,837 sq ft3.1 m / 10 ftPublished dimensions
Pascal12.1 x 12.140 x 40146 m² / 1,576 sq ft3.1 m / 10 ftPublished dimensions
Tesla8.4 x 8.428 x 2871 m² / 760 sq ft3.1 m / 10 ftPublished dimensions
Kelvin7.7 x 7.725 x 2559 m² / 638 sq ft3.1 m / 10 ftPublished dimensions
Newton7.7 x 7.725 x 2559 m² / 638 sq ft3.1 m / 10 ftPublished dimensions
Group rooms4.4 x 4.414 x 1419 m² / 209 sq ft3.1 m / 10 ftPublished dimensions
L’s Kitchen0.3 x 0.31 x 10 m² / 1 sq ft3.1 m / 10 ftPublished dimensions
L’s Resto0.3 x 0.31 x 10 m² / 1 sq ft3.1 m / 10 ftPublished dimensions

What fits in Lindholmen Conference Hall

With a 3.1 m ceiling, a flown wall of Absen A2 Pro (2.97 mm) runs 33 tiles wide by 2 high (66 tiles, 16.5 x 1 m, 5544 x 336 px) once you keep 1.5 m of trim under the bottom edge. That wall weighs about 660 kg and draws up to 12.2 kW (59 A at 208 V). Floor space after a 12 x 7 m stage seats roughly 811 theater, 332 banquet, or 228 classroom. The previz lets you move the wall, change the tile, and check sightlines from the back row.

PanelPitchWall (cols x rows)SizeResolutionWeightPower (max)
9thPanel DW1.9 S Pro1.875 mm28 x 3 = 8416.8 x 1 m8960 x 540403 kg / 889 lb21.3 kW, 103 A @ 208 V
Absen A2 Pro2.97 mm33 x 2 = 6616.5 x 1 m5544 x 336660 kg / 1,455 lb12.2 kW, 59 A @ 208 V
Absen A3 Pro3.9 mm33 x 2 = 6616.5 x 1 m4224 x 256627 kg / 1,382 lb10.6 kW, 51 A @ 208 V

Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.

Planning notes

No rigging point data is published for this venue yet; plan on ground-supported LED or ask the venue for its rigging plot. 8 of the 8 rooms sit under 3.5 m, which rules out flown LED there and limits ground-stacked walls to about 6 rows of 500 mm tile.

Data source

Published dimensions. Dimensions from the venue's published meeting-space specifications (source). Rooms drawn as boxes use published length x width; square rooms were derived from published area only, so treat their shape as approximate. Venue managers: send a floor plan to upgrade your listing to production-ready.

More venues in Gothenburg · All venues