Lamar-Dixon Expo Center
Lamar-Dixon Expo Center in Gonzales lists 6 event spaces totaling 18,943 m² (203,899 sq ft). The largest is 4H Building at 78.3 x 78.3 m (257 x 257 ft) with a 3.1 m (10 ft) ceiling. The tallest ceiling on the property is 3.1 m (10 ft).
Open 4H Building in 3D previzRooms
| Room | Floor | L x W (m) | L x W (ft) | Area | Ceiling | Rig pts | Data |
|---|---|---|---|---|---|---|---|
| 4H Building | 78.3 x 78.3 | 257 x 257 | 6,131 m² / 65,992 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Outside Arena | 42.7 x 91.4 | 140 x 300 | 3,903 m² / 42,009 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Arena D – Robbie G. Savoy Jr. Arena | 36.6 x 91.4 | 120 x 300 | 3,345 m² / 36,007 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Arena B | 36 x 82.3 | 118 x 270 | 2,963 m² / 31,891 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Trademart | 36.6 x 61 | 120 x 200 | 2,233 m² / 24,031 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Chapel | 19.2 x 19.2 | 63 x 63 | 369 m² / 3,968 sq ft | 3.1 m / 10 ft | Published dimensions |
What fits in 4H Building
With a 3.1 m ceiling, a flown wall of Absen A2 Pro (2.97 mm) runs 125 tiles wide by 2 high (250 tiles, 62.5 x 1 m, 21000 x 336 px) once you keep 1.5 m of trim under the bottom edge. That wall weighs about 2,500 kg and draws up to 46.3 kW (222 A at 208 V). Floor space after a 12 x 7 m stage seats roughly 13,437 theater, 5,497 banquet, or 3,779 classroom. The previz lets you move the wall, change the tile, and check sightlines from the back row.
| Panel | Pitch | Wall (cols x rows) | Size | Resolution | Weight | Power (max) |
|---|---|---|---|---|---|---|
| 9thPanel DW1.9 S Pro | 1.875 mm | 104 x 3 = 312 | 62.4 x 1 m | 33280 x 540 | 1,498 kg / 3,302 lb | 79.2 kW, 381 A @ 208 V |
| Absen A2 Pro | 2.97 mm | 125 x 2 = 250 | 62.5 x 1 m | 21000 x 336 | 2,500 kg / 5,512 lb | 46.3 kW, 222 A @ 208 V |
| Absen A3 Pro | 3.9 mm | 125 x 2 = 250 | 62.5 x 1 m | 16000 x 256 | 2,375 kg / 5,236 lb | 40 kW, 192 A @ 208 V |
Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.
Planning notes
No rigging point data is published for this venue yet; plan on ground-supported LED or ask the venue for its rigging plot. 6 of the 6 rooms sit under 3.5 m, which rules out flown LED there and limits ground-stacked walls to about 6 rows of 500 mm tile.
Data source
Published dimensions. Dimensions from the venue's published meeting-space specifications (source). Rooms drawn as boxes use published length x width; square rooms were derived from published area only, so treat their shape as approximate. Venue managers: send a floor plan to upgrade your listing to production-ready.