Tanner Preserve AV
Home / Venues / Gaylord Pacific Resort & Convention Center / Port Pre-function 3

Port Pre-function 3 at Gaylord Pacific Resort & Convention Center

Published dimensions

Port Pre-function 3 is 53.6 x 4 m (176 x 13 ft), 214 m² (2,308 sq ft), with a 3.7 m (12 ft) ceiling.

Open in 3D previz

Plan view

53.6 m / 176 ft4 m / 13 ft grid 5 m

LED wall that fits

Under a 3.7 m ceiling with 1.5 m trim and 0.3 m clearance you get 3 rows of 500 mm tile flown, which is tight; ground-stack or go lower on trim. Along the 53.6 m wall a Absen A2 Pro wall runs 85 x 3 (14280 x 504 px, 2,550 kg, 47.2 kW).

PanelPitchWall (cols x rows)SizeResolutionWeightPower (max)
9thPanel DW1.9 S Pro1.875 mm71 x 5 = 35542.6 x 1.7 m22720 x 9001,704 kg / 3,757 lb90.2 kW, 434 A @ 208 V
Absen A2 Pro2.97 mm85 x 3 = 25542.5 x 1.5 m14280 x 5042,550 kg / 5,622 lb47.2 kW, 227 A @ 208 V
Absen A3 Pro3.9 mm85 x 3 = 25542.5 x 1.5 m10880 x 3842,423 kg / 5,341 lb40.8 kW, 196 A @ 208 V

Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.

Seating estimate

After a 12 x 7 m stage, Port Pre-function 3 holds about 289 theater seats, 118 banquet seats at rounds of 10, or 81 classroom seats. Back row in theater is roughly 46.6 m from the downstage edge; the previz checks whether the bottom of the wall clears the heads in front.

Other rooms at Gaylord Pacific Resort & Convention Center

Published dimensions (source), fetched 2026-09-05. All rooms at Gaylord Pacific Resort & Convention Center