Published dimensions

Delta B/C/D Lobby is 68.3 x 21.3 m (224 x 70 ft), 1,455 m² (15,659 sq ft), with a 7.3 m (24 ft) ceiling.

Open in 3D previz

Plan view

68.3 m / 224 ft21.3 m / 70 ft grid 10 m

LED wall that fits

Under a 7.3 m ceiling with 1.5 m trim and 0.3 m clearance you get 11 rows of 500 mm tile flown. Along the 68.3 m wall a Absen A2 Pro wall runs 109 x 11 (18312 x 1848 px, 11,990 kg, 221.8 kW).

PanelPitchWall (cols x rows)SizeResolutionWeightPower (max)
9thPanel DW1.9 S Pro1.875 mm91 x 16 = 145654.6 x 5.4 m29120 x 28806,989 kg / 15,408 lb369.8 kW, 1778 A @ 208 V
Absen A2 Pro2.97 mm109 x 11 = 119954.5 x 5.5 m18312 x 184811,990 kg / 26,433 lb221.8 kW, 1066 A @ 208 V
Absen A3 Pro3.9 mm109 x 11 = 119954.5 x 5.5 m13952 x 140811,391 kg / 25,111 lb191.8 kW, 922 A @ 208 V

Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.

Seating estimate

After a 12 x 7 m stage, Delta B/C/D Lobby holds about 3,046 theater seats, 1,246 banquet seats at rounds of 10, or 856 classroom seats. Back row in theater is roughly 61.3 m from the downstage edge; the previz checks whether the bottom of the wall clears the heads in front.

Other rooms at Gaylord Opryland Resort & Convention Center

Published dimensions (source), fetched 2026-09-05. All rooms at Gaylord Opryland Resort & Convention Center