The Qube Convention Center
The Qube Convention Center in Gardermoen lists 7 event spaces totaling 12,459 m² (134,107 sq ft). The largest is Qube 1-2 at 86 x 68 m (282 x 223 ft) with a 8 m (26 ft) ceiling. The tallest ceiling on the property is 8 m (26 ft).
Open Qube 1-2 in 3D previzRooms
| Room | Floor | L x W (m) | L x W (ft) | Area | Ceiling | Rig pts | Data |
|---|---|---|---|---|---|---|---|
| Qube 1-2 | 86 x 68 | 282 x 223 | 5,848 m² / 62,947 sq ft | 8 m / 26 ft | Published dimensions | ||
| Qube 1 | 42 x 68 | 138 x 223 | 2,856 m² / 30,742 sq ft | 8 m / 26 ft | Published dimensions | ||
| Qube 2 | 42 x 68 | 138 x 223 | 2,856 m² / 30,742 sq ft | 8 m / 26 ft | Published dimensions | ||
| Qube 3 | 20.2 x 20.2 | 66 x 66 | 408 m² / 4,392 sq ft | 4.3 m / 14 ft | Published dimensions | ||
| Qube 4 | 17 x 17 | 56 x 56 | 289 m² / 3,111 sq ft | 4.3 m / 14 ft | Published dimensions | ||
| Qube 5 | 10.1 x 10.1 | 33 x 33 | 102 m² / 1,098 sq ft | 3.8 m / 12 ft | Published dimensions | ||
| Qube 6 | 10 x 10 | 33 x 33 | 100 m² / 1,076 sq ft | 3.8 m / 12 ft | Published dimensions |
What fits in Qube 1-2
With a 8 m ceiling, a flown wall of Absen A2 Pro (2.97 mm) runs 137 tiles wide by 12 high (1644 tiles, 68.5 x 6 m, 23016 x 2016 px) once you keep 1.5 m of trim under the bottom edge. That wall weighs about 16,440 kg and draws up to 304.1 kW (1462 A at 208 V). Floor space after a 12 x 7 m stage seats roughly 12,808 theater, 5,240 banquet, or 3,602 classroom. The previz lets you move the wall, change the tile, and check sightlines from the back row.
| Panel | Pitch | Wall (cols x rows) | Size | Resolution | Weight | Power (max) |
|---|---|---|---|---|---|---|
| 9thPanel DW1.9 S Pro | 1.875 mm | 114 x 18 = 2052 | 68.4 x 6.1 m | 36480 x 3240 | 9,850 kg / 21,714 lb | 521.2 kW, 2506 A @ 208 V |
| Absen A2 Pro | 2.97 mm | 137 x 12 = 1644 | 68.5 x 6 m | 23016 x 2016 | 16,440 kg / 36,244 lb | 304.1 kW, 1462 A @ 208 V |
| Absen A3 Pro | 3.9 mm | 137 x 12 = 1644 | 68.5 x 6 m | 17536 x 1536 | 15,618 kg / 34,431 lb | 263 kW, 1265 A @ 208 V |
Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.
Planning notes
No rigging point data is published for this venue yet; plan on ground-supported LED or ask the venue for its rigging plot. Every room here clears 3.5 m, so ground-stacked LED works throughout.
Data source
Published dimensions. Dimensions from the venue's published meeting-space specifications (source). Rooms drawn as boxes use published length x width; square rooms were derived from published area only, so treat their shape as approximate. Venue managers: send a floor plan to upgrade your listing to production-ready.