Sandy Park Conference & Banqueting Centre
Sandy Park Conference & Banqueting Centre in Exeter lists 6 event spaces totaling 990 m² (10,655 sq ft). The largest is The Exeter Suite at 37 x 10.5 m (121 x 34 ft) with a 2.9 m (9 ft) ceiling. The tallest ceiling on the property is 2.9 m (9 ft).
Open The Exeter Suite in 3D previzRooms
| Room | Floor | L x W (m) | L x W (ft) | Area | Ceiling | Rig pts | Data |
|---|---|---|---|---|---|---|---|
| The Exeter Suite | 37 x 10.5 | 121 x 34 | 389 m² / 4,182 sq ft | 2.9 m / 9 ft | Published dimensions | ||
| The Estuary Suite | 22.7 x 10.5 | 74 x 34 | 238 m² / 2,566 sq ft | 2.6 m / 8 ft | Published dimensions | ||
| The Chiefs Suite | 15.1 x 10.5 | 50 x 34 | 159 m² / 1,706 sq ft | 2.6 m / 8 ft | Published dimensions | ||
| The County Suite | 14.1 x 10.5 | 46 x 34 | 148 m² / 1,593 sq ft | 2.6 m / 8 ft | Published dimensions | ||
| Baxter Suite | 7.5 x 5 | 25 x 16 | 38 m² / 404 sq ft | 2.6 m / 8 ft | Published dimensions | ||
| Seminar Suite | 3.8 x 5 | 12 x 16 | 19 m² / 205 sq ft | 2.6 m / 8 ft | Published dimensions |
What fits in The Exeter Suite
With a 2.9 m ceiling, a flown wall of Absen A2 Pro (2.97 mm) runs 59 tiles wide by 2 high (118 tiles, 29.5 x 1 m, 9912 x 336 px) once you keep 1.5 m of trim under the bottom edge. That wall weighs about 1,180 kg and draws up to 21.8 kW (105 A at 208 V). Floor space after a 12 x 7 m stage seats roughly 676 theater, 276 banquet, or 190 classroom. The previz lets you move the wall, change the tile, and check sightlines from the back row.
| Panel | Pitch | Wall (cols x rows) | Size | Resolution | Weight | Power (max) |
|---|---|---|---|---|---|---|
| 9thPanel DW1.9 S Pro | 1.875 mm | 49 x 3 = 147 | 29.4 x 1 m | 15680 x 540 | 706 kg / 1,556 lb | 37.3 kW, 180 A @ 208 V |
| Absen A2 Pro | 2.97 mm | 59 x 2 = 118 | 29.5 x 1 m | 9912 x 336 | 1,180 kg / 2,601 lb | 21.8 kW, 105 A @ 208 V |
| Absen A3 Pro | 3.9 mm | 59 x 2 = 118 | 29.5 x 1 m | 7552 x 256 | 1,121 kg / 2,471 lb | 18.9 kW, 91 A @ 208 V |
Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.
Planning notes
No rigging point data is published for this venue yet; plan on ground-supported LED or ask the venue for its rigging plot. 6 of the 6 rooms sit under 3.5 m, which rules out flown LED there and limits ground-stacked walls to about 6 rows of 500 mm tile. The Exeter Suite is a long room (3.5:1), so put the wall on the short end and expect the back row to be 37 m out; a 2.97 mm pitch holds up at that distance.
Data source
Published dimensions. Dimensions from the venue's published meeting-space specifications (source). Rooms drawn as boxes use published length x width; shapes are as published. Venue managers: send a floor plan to upgrade your listing to production-ready.