Published dimensionsEssen

Grugahalle in Essen lists 4 event spaces totaling 5,910 m² (63,618 sq ft). The largest is Hall at 53.6 x 53.6 m (176 x 176 ft) with a 3.1 m (10 ft) ceiling. The tallest ceiling on the property is 3.1 m (10 ft).

Open Hall in 3D previz

Rooms

RoomFloorL x W (m)L x W (ft)AreaCeilingRig ptsData
Hall53.6 x 53.6176 x 1762,873 m² / 30,925 sq ft3.1 m / 10 ftPublished dimensions
Foyer75 x 35246 x 1152,625 m² / 28,255 sq ft2.4 m / 8 ftPublished dimensions
Raum G18 x 1359 x 43234 m² / 2,519 sq ft3 m / 10 ftPublished dimensions
Raum H15.5 x 11.551 x 38178 m² / 1,919 sq ft2.9 m / 10 ftPublished dimensions

What fits in Hall

With a 3.1 m ceiling, a flown wall of Absen A2 Pro (2.97 mm) runs 85 tiles wide by 2 high (170 tiles, 42.5 x 1 m, 14280 x 336 px) once you keep 1.5 m of trim under the bottom edge. That wall weighs about 1,700 kg and draws up to 31.5 kW (151 A at 208 V). Floor space after a 12 x 7 m stage seats roughly 6,197 theater, 2,535 banquet, or 1,743 classroom. The previz lets you move the wall, change the tile, and check sightlines from the back row.

PanelPitchWall (cols x rows)SizeResolutionWeightPower (max)
9thPanel DW1.9 S Pro1.875 mm71 x 3 = 21342.6 x 1 m22720 x 5401,022 kg / 2,254 lb54.1 kW, 260 A @ 208 V
Absen A2 Pro2.97 mm85 x 2 = 17042.5 x 1 m14280 x 3361,700 kg / 3,748 lb31.5 kW, 151 A @ 208 V
Absen A3 Pro3.9 mm85 x 2 = 17042.5 x 1 m10880 x 2561,615 kg / 3,560 lb27.2 kW, 131 A @ 208 V

Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.

Planning notes

No rigging point data is published for this venue yet; plan on ground-supported LED or ask the venue for its rigging plot. 4 of the 4 rooms sit under 3.5 m, which rules out flown LED there and limits ground-stacked walls to about 6 rows of 500 mm tile.

Data source

Published dimensions. Dimensions from the venue's published meeting-space specifications (source). Rooms drawn as boxes use published length x width; square rooms were derived from published area only, so treat their shape as approximate. Venue managers: send a floor plan to upgrade your listing to production-ready.