Home / Venues / Dusseldorf / Design Offices Duesseldorf Kaiserteich

Design Offices Duesseldorf Kaiserteich

Published dimensionsDusseldorf

Design Offices Duesseldorf Kaiserteich in Dusseldorf lists 7 event spaces totaling 482 m² (5,189 sq ft). The largest is Training Room I+II at 7.3 x 18.7 m (24 x 61 ft) with a 2.8 m (9 ft) ceiling. The tallest ceiling on the property is 3.1 m (10 ft).

Open Training Room I+II in 3D previz

Rooms

RoomFloorL x W (m)L x W (ft)AreaCeilingRig ptsData
Training Room I+II7.3 x 18.724 x 61137 m² / 1,469 sq ft2.8 m / 9 ftPublished dimensions
Terrasse9.5 x 9.531 x 3190 m² / 972 sq ft3.1 m / 10 ftPublished dimensions
Training Room I7.3 x 10.924 x 3680 m² / 857 sq ft2.8 m / 9 ftPublished dimensions
DO Eatery8.8 x 8.429 x 2874 m² / 795 sq ft2.6 m / 9 ftPublished dimensions
Training Room II5.5 x 7.818 x 2643 m² / 462 sq ft2.8 m / 9 ftPublished dimensions
Meet & Move Room I4.4 x 9.614 x 3142 m² / 454 sq ft2.6 m / 9 ftPublished dimensions
Fireside Room4.4 x 3.814 x 1217 m² / 180 sq ft2.6 m / 9 ftPublished dimensions

What fits in Training Room I+II

With a 2.8 m ceiling, a flown wall of Absen A2 Pro (2.97 mm) runs 29 tiles wide by 1 high (29 tiles, 14.5 x 0.5 m, 4872 x 168 px) once you keep 1.5 m of trim under the bottom edge. That wall weighs about 290 kg and draws up to 5.4 kW (26 A at 208 V). Floor space after a 12 x 7 m stage seats roughly 116 theater, 47 banquet, or 32 classroom. The previz lets you move the wall, change the tile, and check sightlines from the back row.

PanelPitchWall (cols x rows)SizeResolutionWeightPower (max)
9thPanel DW1.9 S Pro1.875 mm24 x 2 = 4814.4 x 0.7 m7680 x 360230 kg / 508 lb12.2 kW, 59 A @ 208 V
Absen A2 Pro2.97 mm29 x 1 = 2914.5 x 0.5 m4872 x 168290 kg / 639 lb5.4 kW, 26 A @ 208 V
Absen A3 Pro3.9 mm29 x 1 = 2914.5 x 0.5 m3712 x 128276 kg / 607 lb4.6 kW, 22 A @ 208 V

Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.

Planning notes

No rigging point data is published for this venue yet; plan on ground-supported LED or ask the venue for its rigging plot. 7 of the 7 rooms sit under 3.5 m, which rules out flown LED there and limits ground-stacked walls to about 6 rows of 500 mm tile.

Data source

Published dimensions. Dimensions from the venue's published meeting-space specifications (source). Rooms drawn as boxes use published length x width; square rooms were derived from published area only, so treat their shape as approximate. Venue managers: send a floor plan to upgrade your listing to production-ready.

More venues in Dusseldorf · All venues