RoomFloorL x W (m)L x W (ft)AreaCeilingRig ptsData
Grand Hall + 4 Section Halls32.7 x 32.7107 x 1071,069 m² / 11,510 sq ft3.1 m / 10 ftPublished dimensions
Ballroom + Dance Hall22.4 x 22.473 x 73502 m² / 5,401 sq ft3.1 m / 10 ftPublished dimensions
Foyer (Ground Floor)20 x 2066 x 66400 m² / 4,306 sq ft3.1 m / 10 ftPublished dimensions
Exhibition Hall17.6 x 17.658 x 58310 m² / 3,335 sq ft3.1 m / 10 ftPublished dimensions
2 Section Halls12.6 x 12.641 x 41159 m² / 1,709 sq ft3.1 m / 10 ftPublished dimensions
Foyer (First Floor)10 x 1033 x 33100 m² / 1,076 sq ft3.1 m / 10 ftPublished dimensions
Foyer (Second Floor)8.9 x 8.929 x 2979 m² / 853 sq ft3.1 m / 10 ftPublished dimensions

What fits in Grand Hall + 4 Section Halls

With a 3.1 m ceiling, a flown wall of Absen A2 Pro (2.97 mm) runs 52 tiles wide by 2 high (104 tiles, 26 x 1 m, 8736 x 336 px) once you keep 1.5 m of trim under the bottom edge. That wall weighs about 1,040 kg and draws up to 19.2 kW (93 A at 208 V). Floor space after a 12 x 7 m stage seats roughly 2,189 theater, 895 banquet, or 615 classroom. The previz lets you move the wall, change the tile, and check sightlines from the back row.

PanelPitchWall (cols x rows)SizeResolutionWeightPower (max)
9thPanel DW1.9 S Pro1.875 mm43 x 3 = 12925.8 x 1 m13760 x 540619 kg / 1,365 lb32.8 kW, 158 A @ 208 V
Absen A2 Pro2.97 mm52 x 2 = 10426 x 1 m8736 x 3361,040 kg / 2,293 lb19.2 kW, 93 A @ 208 V
Absen A3 Pro3.9 mm52 x 2 = 10426 x 1 m6656 x 256988 kg / 2,178 lb16.6 kW, 80 A @ 208 V

Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.

Planning notes

No rigging point data is published for this venue yet; plan on ground-supported LED or ask the venue for its rigging plot. 7 of the 7 rooms sit under 3.5 m, which rules out flown LED there and limits ground-stacked walls to about 6 rows of 500 mm tile.

Data source

Published dimensions. Dimensions from the venue's published meeting-space specifications (source). Rooms drawn as boxes use published length x width; square rooms were derived from published area only, so treat their shape as approximate. Venue managers: send a floor plan to upgrade your listing to production-ready.