Tandem
Tandem in Darlington lists 6 event spaces totaling 418 m² (4,501 sq ft). The largest is Double Conference Room (A&B) at 16.9 x 16.9 m (55 x 55 ft) with a 3.1 m (10 ft) ceiling. The tallest ceiling on the property is 3.1 m (10 ft).
Open Double Conference Room (A&B) in 3D previzRooms
| Room | Floor | L x W (m) | L x W (ft) | Area | Ceiling | Rig pts | Data |
|---|---|---|---|---|---|---|---|
| Double Conference Room (A&B) | 16.9 x 16.9 | 55 x 55 | 286 m² / 3,074 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Single Training Room – Room 1, 5, 6, 7 or 8 | 7.3 x 7.3 | 24 x 24 | 53 m² / 574 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Small Conference Room | 5.3 x 5.3 | 17 x 17 | 28 m² / 302 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Syndicate Room 3 | 5.3 x 5.3 | 17 x 17 | 28 m² / 302 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Syndicate Room 2 | 4.7 x 4.7 | 15 x 15 | 22 m² / 238 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Boardroom | 1 x 1 | 3 x 3 | 1 m² / 11 sq ft | 3.1 m / 10 ft | Published dimensions |
What fits in Double Conference Room (A&B)
With a 3.1 m ceiling, a flown wall of Absen A2 Pro (2.97 mm) runs 27 tiles wide by 2 high (54 tiles, 13.5 x 1 m, 4536 x 336 px) once you keep 1.5 m of trim under the bottom edge. That wall weighs about 540 kg and draws up to 10 kW (48 A at 208 V). Floor space after a 12 x 7 m stage seats roughly 448 theater, 183 banquet, or 126 classroom. The previz lets you move the wall, change the tile, and check sightlines from the back row.
| Panel | Pitch | Wall (cols x rows) | Size | Resolution | Weight | Power (max) |
|---|---|---|---|---|---|---|
| 9thPanel DW1.9 S Pro | 1.875 mm | 22 x 3 = 66 | 13.2 x 1 m | 7040 x 540 | 317 kg / 698 lb | 16.8 kW, 81 A @ 208 V |
| Absen A2 Pro | 2.97 mm | 27 x 2 = 54 | 13.5 x 1 m | 4536 x 336 | 540 kg / 1,190 lb | 10 kW, 48 A @ 208 V |
| Absen A3 Pro | 3.9 mm | 27 x 2 = 54 | 13.5 x 1 m | 3456 x 256 | 513 kg / 1,131 lb | 8.6 kW, 42 A @ 208 V |
Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.
Planning notes
No rigging point data is published for this venue yet; plan on ground-supported LED or ask the venue for its rigging plot. 6 of the 6 rooms sit under 3.5 m, which rules out flown LED there and limits ground-stacked walls to about 6 rows of 500 mm tile.
Data source
Published dimensions. Dimensions from the venue's published meeting-space specifications (source). Rooms drawn as boxes use published length x width; square rooms were derived from published area only, so treat their shape as approximate. Venue managers: send a floor plan to upgrade your listing to production-ready.