Hampton Inn & Suites Dallas Downtown
Hampton Inn & Suites Dallas Downtown in Dallas lists 3 event spaces totaling 379 m² (4,076 sq ft). The largest is Trinity Meeting Room at 27.1 x 11.9 m (89 x 39 ft) with a 3 m (10 ft) ceiling. The tallest ceiling on the property is 3 m (10 ft).
Open Trinity Meeting Room in 3D previzRooms
| Room | Floor | L x W (m) | L x W (ft) | Area | Ceiling | Rig pts | Data |
|---|---|---|---|---|---|---|---|
| Trinity Meeting Room | 27.1 x 11.9 | 89 x 39 | 323 m² / 3,471 sq ft | 3 m / 10 ft | Published dimensions | ||
| Brazos Boardroom | 7.6 x 3.7 | 25 x 12 | 28 m² / 302 sq ft | 3 m / 10 ft | Published dimensions | ||
| Hampton Boardroom | 7.6 x 3.7 | 25 x 12 | 28 m² / 302 sq ft | 3 m / 10 ft | Published dimensions |
What fits in Trinity Meeting Room
With a 3 m ceiling, a flown wall of Absen A2 Pro (2.97 mm) runs 43 tiles wide by 2 high (86 tiles, 21.5 x 1 m, 7224 x 336 px) once you keep 1.5 m of trim under the bottom edge. That wall weighs about 860 kg and draws up to 15.9 kW (76 A at 208 V). Floor space after a 12 x 7 m stage seats roughly 530 theater, 216 banquet, or 149 classroom. The previz lets you move the wall, change the tile, and check sightlines from the back row.
| Panel | Pitch | Wall (cols x rows) | Size | Resolution | Weight | Power (max) |
|---|---|---|---|---|---|---|
| 9thPanel DW1.9 S Pro | 1.875 mm | 36 x 3 = 108 | 21.6 x 1 m | 11520 x 540 | 518 kg / 1,143 lb | 27.4 kW, 132 A @ 208 V |
| Absen A2 Pro | 2.97 mm | 43 x 2 = 86 | 21.5 x 1 m | 7224 x 336 | 860 kg / 1,896 lb | 15.9 kW, 76 A @ 208 V |
| Absen A3 Pro | 3.9 mm | 43 x 2 = 86 | 21.5 x 1 m | 5504 x 256 | 817 kg / 1,801 lb | 13.8 kW, 66 A @ 208 V |
Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.
Planning notes
No rigging point data is published for this venue yet; plan on ground-supported LED or ask the venue for its rigging plot. 3 of the 3 rooms sit under 3.5 m, which rules out flown LED there and limits ground-stacked walls to about 6 rows of 500 mm tile. Trinity Meeting Room is a long room (2.3:1), so put the wall on the short end and expect the back row to be 27.1 m out; a 2.97 mm pitch holds up at that distance.
Data source
Published dimensions. Dimensions from the venue's published meeting-space specifications (source). Rooms drawn as boxes use published length x width; shapes are as published. Venue managers: send a floor plan to upgrade your listing to production-ready.