The Medallion Conference Center

Published dimensionsColumbia

The Medallion Conference Center in Columbia lists 8 event spaces totaling 3,418 m² (36,796 sq ft). The largest is The Grand Medallion Ballroom at 27.1 x 48.8 m (89 x 160 ft) with a 5.5 m (18 ft) ceiling. The tallest ceiling on the property is 5.5 m (18 ft).

Open The Grand Medallion Ballroom in 3D previz

Rooms

RoomFloorL x W (m)L x W (ft)AreaCeilingRig ptsData
The Grand Medallion Ballroom27.1 x 48.889 x 1601,323 m² / 14,235 sq ft5.5 m / 18 ftPublished dimensions
Salon A27.1 x 24.189 x 79653 m² / 7,030 sq ft5.5 m / 18 ftPublished dimensions
The Capital City Salon21 x 2169 x 69441 m² / 4,747 sq ft5.5 m / 18 ftPublished dimensions
Salon C27.1 x 13.189 x 43355 m² / 3,821 sq ft5.5 m / 18 ftPublished dimensions
Salon B27.1 x 11.989 x 39323 m² / 3,471 sq ft5.5 m / 18 ftPublished dimensions
The Congaree Room11.6 x 1238 x 39139 m² / 1,498 sq ft5.5 m / 18 ftPublished dimensions
The Broad Room9.8 x 9.832 x 3296 m² / 1,033 sq ft5.5 m / 18 ftPublished dimensions
The Saluda Room9.8 x 9.132 x 3089 m² / 960 sq ft5.5 m / 18 ftPublished dimensions

What fits in The Grand Medallion Ballroom

With a 5.5 m ceiling, a flown wall of Absen A2 Pro (2.97 mm) runs 78 tiles wide by 7 high (546 tiles, 39 x 3.5 m, 13104 x 1176 px) once you keep 1.5 m of trim under the bottom edge. That wall weighs about 5,460 kg and draws up to 101 kW (486 A at 208 V). Floor space after a 12 x 7 m stage seats roughly 2,752 theater, 1,125 banquet, or 774 classroom. The previz lets you move the wall, change the tile, and check sightlines from the back row.

PanelPitchWall (cols x rows)SizeResolutionWeightPower (max)
9thPanel DW1.9 S Pro1.875 mm65 x 10 = 65039 x 3.4 m20800 x 18003,120 kg / 6,878 lb165.1 kW, 794 A @ 208 V
Absen A2 Pro2.97 mm78 x 7 = 54639 x 3.5 m13104 x 11765,460 kg / 12,037 lb101 kW, 486 A @ 208 V
Absen A3 Pro3.9 mm78 x 7 = 54639 x 3.5 m9984 x 8965,187 kg / 11,435 lb87.4 kW, 420 A @ 208 V

Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.

Planning notes

No rigging point data is published for this venue yet; plan on ground-supported LED or ask the venue for its rigging plot. Every room here clears 3.5 m, so ground-stacked LED works throughout.

Data source

Published dimensions. Dimensions from the venue's published meeting-space specifications (source). Rooms drawn as boxes use published length x width; square rooms were derived from published area only, so treat their shape as approximate. Venue managers: send a floor plan to upgrade your listing to production-ready.

More venues in Columbia · All venues