Main Room at Wayne Nickum Town Hall
Main Room is 12.2 x 15.2 m (40 x 50 ft), 185 m² (1,996 sq ft), with a 3.7 m (12 ft) ceiling.
Open in 3D previzPlan view
LED wall that fits
Under a 3.7 m ceiling with 1.5 m trim and 0.3 m clearance you get 3 rows of 500 mm tile flown, which is tight; ground-stack or go lower on trim. Along the 15.2 m wall a Absen A2 Pro wall runs 24 x 3 (4032 x 504 px, 720 kg, 13.3 kW).
| Panel | Pitch | Wall (cols x rows) | Size | Resolution | Weight | Power (max) |
|---|---|---|---|---|---|---|
| 9thPanel DW1.9 S Pro | 1.875 mm | 20 x 5 = 100 | 12 x 1.7 m | 6400 x 900 | 480 kg / 1,058 lb | 25.4 kW, 122 A @ 208 V |
| Absen A2 Pro | 2.97 mm | 24 x 3 = 72 | 12 x 1.5 m | 4032 x 504 | 720 kg / 1,587 lb | 13.3 kW, 64 A @ 208 V |
| Absen A3 Pro | 3.9 mm | 24 x 3 = 72 | 12 x 1.5 m | 3072 x 384 | 684 kg / 1,508 lb | 11.5 kW, 55 A @ 208 V |
Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.
Seating estimate
After a 12 x 7 m stage, Main Room holds about 225 theater seats, 92 banquet seats at rounds of 10, or 63 classroom seats. Back row in theater is roughly 8.2 m from the downstage edge; the previz checks whether the bottom of the wall clears the heads in front.
Published dimensions (source), fetched 2026-09-05. All rooms at Wayne Nickum Town Hall · Venues in Clifton