Published dimensions

Veterans Meeting Room is 7.3 x 35.4 m (24 x 116 ft), 258 m² (2,781 sq ft), with a 3.4 m (11 ft) ceiling.

Open in 3D previz

Plan view

7.3 m / 24 ft35.4 m / 116 ft grid 5 m

LED wall that fits

Under a 3.4 m ceiling with 1.5 m trim and 0.3 m clearance you get 3 rows of 500 mm tile flown, which is tight; ground-stack or go lower on trim. Along the 35.4 m wall a Absen A2 Pro wall runs 56 x 3 (9408 x 504 px, 1,680 kg, 31.1 kW).

PanelPitchWall (cols x rows)SizeResolutionWeightPower (max)
9thPanel DW1.9 S Pro1.875 mm47 x 4 = 18828.2 x 1.4 m15040 x 720902 kg / 1,989 lb47.8 kW, 230 A @ 208 V
Absen A2 Pro2.97 mm56 x 3 = 16828 x 1.5 m9408 x 5041,680 kg / 3,704 lb31.1 kW, 149 A @ 208 V
Absen A3 Pro3.9 mm56 x 3 = 16828 x 1.5 m7168 x 3841,596 kg / 3,519 lb26.9 kW, 129 A @ 208 V

Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.

Seating estimate

After a 12 x 7 m stage, Veterans Meeting Room holds about 387 theater seats, 158 banquet seats at rounds of 10, or 108 classroom seats. Back row in theater is roughly 28.4 m from the downstage edge; the previz checks whether the bottom of the wall clears the heads in front.