Published dimensions

4th Floor Pre-Function Area is 34.7 x 7 m (114 x 23 ft), 243 m² (2,615 sq ft), with a 4 m (13 ft) ceiling.

Open in 3D previz

Plan view

34.7 m / 114 ft7 m / 23 ft grid 5 m

LED wall that fits

Under a 4 m ceiling with 1.5 m trim and 0.3 m clearance you get 4 rows of 500 mm tile flown. Along the 34.7 m wall a Absen A2 Pro wall runs 55 x 4 (9240 x 672 px, 2,200 kg, 40.7 kW).

PanelPitchWall (cols x rows)SizeResolutionWeightPower (max)
9thPanel DW1.9 S Pro1.875 mm46 x 6 = 27627.6 x 2 m14720 x 10801,325 kg / 2,921 lb70.1 kW, 337 A @ 208 V
Absen A2 Pro2.97 mm55 x 4 = 22027.5 x 2 m9240 x 6722,200 kg / 4,850 lb40.7 kW, 196 A @ 208 V
Absen A3 Pro3.9 mm55 x 4 = 22027.5 x 2 m7040 x 5122,090 kg / 4,608 lb35.2 kW, 169 A @ 208 V

Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.

Seating estimate

After a 12 x 7 m stage, 4th Floor Pre-Function Area holds about 353 theater seats, 144 banquet seats at rounds of 10, or 99 classroom seats. Back row in theater is roughly 27.7 m from the downstage edge; the previz checks whether the bottom of the wall clears the heads in front.