Soldier Field
Soldier Field in Chicago lists 6 event spaces totaling 7,386 m² (79,502 sq ft). The largest is 1st Floor United Club at 66.8 x 66.8 m (219 x 219 ft) with a 6.1 m (20 ft) ceiling. The tallest ceiling on the property is 6.1 m (20 ft).
Open 1st Floor United Club in 3D previzRooms
| Room | Floor | L x W (m) | L x W (ft) | Area | Ceiling | Rig pts | Data |
|---|---|---|---|---|---|---|---|
| 1st Floor United Club | 66.8 x 66.8 | 219 x 219 | 4,462 m² / 48,031 sq ft | 6.1 m / 20 ft | Published dimensions | ||
| Colonnades | 34.1 x 34.1 | 112 x 112 | 1,163 m² / 12,516 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| 3rd Floor United Club | 30.5 x 30.5 | 100 x 100 | 930 m² / 10,014 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Skyline Suite | 26.8 x 26.8 | 88 x 88 | 718 m² / 7,731 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Visitor's Locker Room | 10.6 x 10.6 | 35 x 35 | 112 m² / 1,210 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Press Box | 0.3 x 0.3 | 1 x 1 | 0 m² / 1 sq ft | 3.1 m / 10 ft | Published dimensions |
What fits in 1st Floor United Club
With a 6.1 m ceiling, a flown wall of Absen A2 Pro (2.97 mm) runs 106 tiles wide by 8 high (848 tiles, 53 x 4 m, 17808 x 1344 px) once you keep 1.5 m of trim under the bottom edge. That wall weighs about 8,480 kg and draws up to 156.9 kW (754 A at 208 V). Floor space after a 12 x 7 m stage seats roughly 9,729 theater, 3,980 banquet, or 2,736 classroom. The previz lets you move the wall, change the tile, and check sightlines from the back row.
| Panel | Pitch | Wall (cols x rows) | Size | Resolution | Weight | Power (max) |
|---|---|---|---|---|---|---|
| 9thPanel DW1.9 S Pro | 1.875 mm | 89 x 12 = 1068 | 53.4 x 4.1 m | 28480 x 2160 | 5,126 kg / 11,302 lb | 271.3 kW, 1304 A @ 208 V |
| Absen A2 Pro | 2.97 mm | 106 x 8 = 848 | 53 x 4 m | 17808 x 1344 | 8,480 kg / 18,695 lb | 156.9 kW, 754 A @ 208 V |
| Absen A3 Pro | 3.9 mm | 106 x 8 = 848 | 53 x 4 m | 13568 x 1024 | 8,056 kg / 17,760 lb | 135.7 kW, 652 A @ 208 V |
Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.
Planning notes
No rigging point data is published for this venue yet; plan on ground-supported LED or ask the venue for its rigging plot. 5 of the 6 rooms sit under 3.5 m, which rules out flown LED there and limits ground-stacked walls to about 6 rows of 500 mm tile.
Data source
Published dimensions. Dimensions from the venue's published meeting-space specifications (source). Rooms drawn as boxes use published length x width; square rooms were derived from published area only, so treat their shape as approximate. Venue managers: send a floor plan to upgrade your listing to production-ready.