Homewood Suites by Hilton Chicago Downtown
Homewood Suites by Hilton Chicago Downtown in Chicago lists 7 event spaces totaling 414 m² (4,458 sq ft). The largest is The Grand Ave Room at 7 x 14 m (23 x 46 ft) with a 2.4 m (8 ft) ceiling. The tallest ceiling on the property is 2.4 m (8 ft).
Open The Grand Ave Room in 3D previzRooms
| Room | Floor | L x W (m) | L x W (ft) | Area | Ceiling | Rig pts | Data |
|---|---|---|---|---|---|---|---|
| The Grand Ave Room | 7 x 14 | 23 x 46 | 98 m² / 1,055 sq ft | 2.4 m / 8 ft | Published dimensions | ||
| The Grand Avenue Room | 14 x 7 | 46 x 23 | 98 m² / 1,055 sq ft | 2.4 m / 8 ft | Published dimensions | ||
| Grand North | 7.9 x 7 | 26 x 23 | 55 m² / 595 sq ft | 2.4 m / 8 ft | Published dimensions | ||
| Semi-Private Dining | 4.3 x 12.2 | 14 x 40 | 53 m² / 565 sq ft | 2.4 m / 8 ft | Published dimensions | ||
| Grand South | 6.1 x 7 | 20 x 23 | 43 m² / 460 sq ft | 2.4 m / 8 ft | Published dimensions | ||
| The Ohio Room | 4.9 x 8.2 | 16 x 27 | 40 m² / 433 sq ft | 2.4 m / 8 ft | Published dimensions | ||
| The Wabash Boardroom | 6.4 x 4.3 | 21 x 14 | 28 m² / 296 sq ft | 2.4 m / 8 ft | Published dimensions |
What fits in The Grand Ave Room
With a 2.4 m ceiling, a flown wall of Absen A2 Pro (2.97 mm) runs 22 tiles wide by 1 high (22 tiles, 11 x 0.5 m, 3696 x 168 px) once you keep 1.5 m of trim under the bottom edge. That wall weighs about 220 kg and draws up to 4.1 kW (20 A at 208 V). Floor space after a 12 x 7 m stage seats roughly 31 theater, 12 banquet, or 8 classroom. The previz lets you move the wall, change the tile, and check sightlines from the back row.
| Panel | Pitch | Wall (cols x rows) | Size | Resolution | Weight | Power (max) |
|---|---|---|---|---|---|---|
| 9thPanel DW1.9 S Pro | 1.875 mm | 18 x 1 = 18 | 10.8 x 0.3 m | 5760 x 180 | 86 kg / 190 lb | 4.6 kW, 22 A @ 208 V |
| Absen A2 Pro | 2.97 mm | 22 x 1 = 22 | 11 x 0.5 m | 3696 x 168 | 220 kg / 485 lb | 4.1 kW, 20 A @ 208 V |
| Absen A3 Pro | 3.9 mm | 22 x 1 = 22 | 11 x 0.5 m | 2816 x 128 | 209 kg / 461 lb | 3.5 kW, 17 A @ 208 V |
Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.
Planning notes
No rigging point data is published for this venue yet; plan on ground-supported LED or ask the venue for its rigging plot. 7 of the 7 rooms sit under 3.5 m, which rules out flown LED there and limits ground-stacked walls to about 6 rows of 500 mm tile.
Data source
Published dimensions. Dimensions from the venue's published meeting-space specifications (source). Rooms drawn as boxes use published length x width; shapes are as published. Venue managers: send a floor plan to upgrade your listing to production-ready.