Hall No. 2 at Chennai Convention Centre

Published dimensions

Hall No. 2 is 40 x 44 m (131 x 144 ft), 1,760 m² (18,944 sq ft), with a 6 m (20 ft) ceiling.

Open in 3D previz

Plan view

40 m / 131 ft44 m / 144 ft grid 5 m

LED wall that fits

Under a 6 m ceiling with 1.5 m trim and 0.3 m clearance you get 8 rows of 500 mm tile flown. Along the 44 m wall a Absen A2 Pro wall runs 70 x 8 (11760 x 1344 px, 5,600 kg, 103.6 kW).

PanelPitchWall (cols x rows)SizeResolutionWeightPower (max)
9thPanel DW1.9 S Pro1.875 mm58 x 12 = 69634.8 x 4.1 m18560 x 21603,341 kg / 7,365 lb176.8 kW, 850 A @ 208 V
Absen A2 Pro2.97 mm70 x 8 = 56035 x 4 m11760 x 13445,600 kg / 12,346 lb103.6 kW, 498 A @ 208 V
Absen A3 Pro3.9 mm70 x 8 = 56035 x 4 m8960 x 10245,320 kg / 11,728 lb89.6 kW, 431 A @ 208 V

Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.

Seating estimate

After a 12 x 7 m stage, Hall No. 2 holds about 3,724 theater seats, 1,523 banquet seats at rounds of 10, or 1,047 classroom seats. Back row in theater is roughly 37 m from the downstage edge; the previz checks whether the bottom of the wall clears the heads in front.

Other rooms at Chennai Convention Centre

Published dimensions (source), fetched 2026-09-05. All rooms at Chennai Convention Centre · Venues in Chennai