Tanner Preserve AV
Home / Venues / Charlotte / Venues at Station West

Venues at Station West

Published dimensionsCharlotte

Venues at Station West in Charlotte lists 8 event spaces totaling 1,283 m² (13,811 sq ft). The largest is The Union at 26.8 x 26.8 m (88 x 88 ft) with a 4.9 m (16 ft) ceiling. The tallest ceiling on the property is 4.9 m (16 ft).

Open The Union in 3D previz

Rooms

RoomFloorL x W (m)L x W (ft)AreaCeilingRig ptsData
The Union26.8 x 26.888 x 88718 m² / 7,731 sq ft4.9 m / 16 ftPublished dimensions
The Crossing14.2 x 14.247 x 47202 m² / 2,170 sq ft4.9 m / 16 ftPublished dimensions
Platform Coffee + Kitchen10.2 x 10.233 x 33104 m² / 1,119 sq ft4.9 m / 16 ftPublished dimensions
Plaza (Outdoor Space)9.6 x 9.631 x 3192 m² / 992 sq ft3.1 m / 10 ftPublished dimensions
Spurline Studio8.3 x 8.327 x 2769 m² / 742 sq ft3.1 m / 10 ftPublished dimensions
Westbound and Eastbound6.8 x 6.822 x 2246 m² / 497 sq ft4.9 m / 16 ftPublished dimensions
Platform Coffee Conference Room5.2 x 5.217 x 1727 m² / 291 sq ft4.9 m / 16 ftPublished dimensions
Blue Jay Conference Room5 x 516 x 1625 m² / 269 sq ft4.9 m / 16 ftPublished dimensions

What fits in The Union

With a 4.9 m ceiling, a flown wall of Absen A2 Pro (2.97 mm) runs 42 tiles wide by 6 high (252 tiles, 21 x 3 m, 7056 x 1008 px) once you keep 1.5 m of trim under the bottom edge. That wall weighs about 2,520 kg and draws up to 46.6 kW (224 A at 208 V). Floor space after a 12 x 7 m stage seats roughly 1,409 theater, 576 banquet, or 396 classroom. The previz lets you move the wall, change the tile, and check sightlines from the back row.

PanelPitchWall (cols x rows)SizeResolutionWeightPower (max)
9thPanel DW1.9 S Pro1.875 mm35 x 9 = 31521 x 3 m11200 x 16201,512 kg / 3,333 lb80 kW, 385 A @ 208 V
Absen A2 Pro2.97 mm42 x 6 = 25221 x 3 m7056 x 10082,520 kg / 5,556 lb46.6 kW, 224 A @ 208 V
Absen A3 Pro3.9 mm42 x 6 = 25221 x 3 m5376 x 7682,394 kg / 5,278 lb40.3 kW, 194 A @ 208 V

Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.

Planning notes

No rigging point data is published for this venue yet; plan on ground-supported LED or ask the venue for its rigging plot. 2 of the 8 rooms sit under 3.5 m, which rules out flown LED there and limits ground-stacked walls to about 6 rows of 500 mm tile.

Data source

Published dimensions. Dimensions from the venue's published meeting-space specifications (source). Rooms drawn as boxes use published length x width; square rooms were derived from published area only, so treat their shape as approximate. Venue managers: send a floor plan to upgrade your listing to production-ready.

More venues in Charlotte · All venues