Tanner Preserve AV
Home / Venues / Calgary TELUS Convention Centre / Macleod Hall A1, A2, A3 & A4

Macleod Hall A1, A2, A3 & A4 at Calgary TELUS Convention Centre

Published dimensions

Macleod Hall A1, A2, A3 & A4 is 27.8 x 11.5 m (91 x 38 ft), 320 m² (3,441 sq ft), with a 3.1 m (10 ft) ceiling.

Open in 3D previz

Plan view

27.8 m / 91 ft11.5 m / 38 ft grid 5 m

LED wall that fits

Under a 3.1 m ceiling with 1.5 m trim and 0.3 m clearance you get 2 rows of 500 mm tile flown, which is tight; ground-stack or go lower on trim. Along the 27.8 m wall a Absen A2 Pro wall runs 44 x 2 (7392 x 336 px, 880 kg, 16.3 kW).

PanelPitchWall (cols x rows)SizeResolutionWeightPower (max)
9thPanel DW1.9 S Pro1.875 mm37 x 3 = 11122.2 x 1 m11840 x 540533 kg / 1,175 lb28.2 kW, 136 A @ 208 V
Absen A2 Pro2.97 mm44 x 2 = 8822 x 1 m7392 x 336880 kg / 1,940 lb16.3 kW, 78 A @ 208 V
Absen A3 Pro3.9 mm44 x 2 = 8822 x 1 m5632 x 256836 kg / 1,843 lb14.1 kW, 68 A @ 208 V

Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.

Seating estimate

After a 12 x 7 m stage, Macleod Hall A1, A2, A3 & A4 holds about 523 theater seats, 214 banquet seats at rounds of 10, or 147 classroom seats. Back row in theater is roughly 20.8 m from the downstage edge; the previz checks whether the bottom of the wall clears the heads in front.

Other rooms at Calgary TELUS Convention Centre

Published dimensions (source), fetched 2026-09-05. All rooms at Calgary TELUS Convention Centre · Venues in Calgary