Romexpo S.a.
Romexpo S.a. in Bucharest lists 25 event spaces totaling 28,851 m² (310,555 sq ft). The largest is Hall C4-C5 at 71.5 x 71.5 m (235 x 235 ft) with a 3.1 m (10 ft) ceiling. The tallest ceiling on the property is 4.6 m (15 ft).
Open Hall C4-C5 in 3D previzRooms
| Room | Floor | L x W (m) | L x W (ft) | Area | Ceiling | Rig pts | Data |
|---|---|---|---|---|---|---|---|
| Hall C4-C5 | 71.5 x 71.5 | 235 x 235 | 5,112 m² / 55,028 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Hall C2 | 65.5 x 65.5 | 215 x 215 | 4,290 m² / 46,180 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Hall C3 | 55 x 55 | 180 x 180 | 3,025 m² / 32,561 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Hall C1 | 50.1 x 50.1 | 164 x 164 | 2,510 m² / 27,017 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Hall C6 | 49.9 x 49.9 | 164 x 164 | 2,490 m² / 26,802 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Hall D1 | 39.2 x 39.2 | 129 x 129 | 1,537 m² / 16,540 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Hall D2 | 39.2 x 39.2 | 129 x 129 | 1,537 m² / 16,540 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Hall E1 | 35.8 x 35.8 | 117 x 117 | 1,282 m² / 13,795 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Hall F | 35.7 x 35.7 | 117 x 117 | 1,275 m² / 13,719 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Titulescu Hall | 29.2 x 29.2 | 96 x 96 | 853 m² / 9,177 sq ft | 4.6 m / 15 ft | Published dimensions | ||
| Hall E2 | 28.4 x 28.4 | 93 x 93 | 807 m² / 8,682 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Hall H3 | 26.6 x 26.6 | 87 x 87 | 708 m² / 7,617 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Polivalenta | 22.6 x 22.6 | 74 x 74 | 511 m² / 5,498 sq ft | 2.8 m / 9 ft | Published dimensions | ||
| Hall G4 | 20.5 x 20.5 | 67 x 67 | 420 m² / 4,524 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Hall G1 | 20.3 x 20.3 | 67 x 67 | 412 m² / 4,436 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Hall G2 | 17.9 x 17.9 | 59 x 59 | 320 m² / 3,449 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Medgearu Hall | 17.9 x 17.9 | 59 x 59 | 320 m² / 3,449 sq ft | 2.8 m / 9 ft | Published dimensions | ||
| Balcescu | 17.5 x 17.5 | 57 x 57 | 306 m² / 3,297 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Lorga Hall | 17.5 x 17.5 | 57 x 57 | 306 m² / 3,297 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Hall G5 | 17.3 x 17.3 | 57 x 57 | 299 m² / 3,222 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Cupola | 13.3 x 13.3 | 44 x 44 | 177 m² / 1,904 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Brancusi Hall | 11.8 x 11.8 | 39 x 39 | 139 m² / 1,498 sq ft | 2.8 m / 9 ft | Published dimensions | ||
| Hall G3 | 10.3 x 10.3 | 34 x 34 | 106 m² / 1,142 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Press Point Hall | 7.7 x 7.7 | 25 x 25 | 59 m² / 638 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| VIP | 7.1 x 7.1 | 23 x 23 | 50 m² / 543 sq ft | 3.1 m / 10 ft | Published dimensions |
What fits in Hall C4-C5
With a 3.1 m ceiling, a flown wall of Absen A2 Pro (2.97 mm) runs 114 tiles wide by 2 high (228 tiles, 57 x 1 m, 19152 x 336 px) once you keep 1.5 m of trim under the bottom edge. That wall weighs about 2,280 kg and draws up to 42.2 kW (203 A at 208 V). Floor space after a 12 x 7 m stage seats roughly 11,174 theater, 4,571 banquet, or 3,142 classroom. The previz lets you move the wall, change the tile, and check sightlines from the back row.
| Panel | Pitch | Wall (cols x rows) | Size | Resolution | Weight | Power (max) |
|---|---|---|---|---|---|---|
| 9thPanel DW1.9 S Pro | 1.875 mm | 95 x 3 = 285 | 57 x 1 m | 30400 x 540 | 1,368 kg / 3,016 lb | 72.4 kW, 348 A @ 208 V |
| Absen A2 Pro | 2.97 mm | 114 x 2 = 228 | 57 x 1 m | 19152 x 336 | 2,280 kg / 5,026 lb | 42.2 kW, 203 A @ 208 V |
| Absen A3 Pro | 3.9 mm | 114 x 2 = 228 | 57 x 1 m | 14592 x 256 | 2,166 kg / 4,775 lb | 36.5 kW, 175 A @ 208 V |
Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.
Planning notes
No rigging point data is published for this venue yet; plan on ground-supported LED or ask the venue for its rigging plot. 24 of the 25 rooms sit under 3.5 m, which rules out flown LED there and limits ground-stacked walls to about 6 rows of 500 mm tile.
Data source
Published dimensions. Dimensions from the venue's published meeting-space specifications (source). Rooms drawn as boxes use published length x width; square rooms were derived from published area only, so treat their shape as approximate. Venue managers: send a floor plan to upgrade your listing to production-ready.