Texas 4-H Conference Center at Texas A&M University
Texas 4-H Conference Center at Texas A&M University in Brownwood lists 8 event spaces totaling 1,114 m² (11,991 sq ft). The largest is Auditorium at 23.2 x 12.2 m (76 x 40 ft) with a 3.1 m (10 ft) ceiling. The tallest ceiling on the property is 3.1 m (10 ft).
Open Auditorium in 3D previzRooms
| Room | Floor | L x W (m) | L x W (ft) | Area | Ceiling | Rig pts | Data |
|---|---|---|---|---|---|---|---|
| Auditorium | 23.2 x 12.2 | 76 x 40 | 283 m² / 3,046 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Lakeside Pavilion | 16.8 x 15.2 | 55 x 50 | 255 m² / 2,749 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Covered Patio | 15.2 x 15 | 50 x 49 | 228 m² / 2,454 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Leadership Lodge Conference Area | 14 x 9.4 | 46 x 31 | 132 m² / 1,417 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Recreation Room | 15.2 x 6.7 | 50 x 22 | 102 m² / 1,096 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Moore County Room | 9.4 x 6.7 | 31 x 22 | 63 m² / 678 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Victoria County Room | 7.3 x 7 | 24 x 23 | 51 m² / 550 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Dining Room | 0.3 x 0.3 | 1 x 1 | 0 m² / 1 sq ft | 3.1 m / 10 ft | Published dimensions |
What fits in Auditorium
With a 3.1 m ceiling, a flown wall of Absen A2 Pro (2.97 mm) runs 37 tiles wide by 2 high (74 tiles, 18.5 x 1 m, 6216 x 336 px) once you keep 1.5 m of trim under the bottom edge. That wall weighs about 740 kg and draws up to 13.7 kW (66 A at 208 V). Floor space after a 12 x 7 m stage seats roughly 442 theater, 180 banquet, or 124 classroom. The previz lets you move the wall, change the tile, and check sightlines from the back row.
| Panel | Pitch | Wall (cols x rows) | Size | Resolution | Weight | Power (max) |
|---|---|---|---|---|---|---|
| 9thPanel DW1.9 S Pro | 1.875 mm | 30 x 3 = 90 | 18 x 1 m | 9600 x 540 | 432 kg / 952 lb | 22.9 kW, 110 A @ 208 V |
| Absen A2 Pro | 2.97 mm | 37 x 2 = 74 | 18.5 x 1 m | 6216 x 336 | 740 kg / 1,631 lb | 13.7 kW, 66 A @ 208 V |
| Absen A3 Pro | 3.9 mm | 37 x 2 = 74 | 18.5 x 1 m | 4736 x 256 | 703 kg / 1,550 lb | 11.8 kW, 57 A @ 208 V |
Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.
Planning notes
No rigging point data is published for this venue yet; plan on ground-supported LED or ask the venue for its rigging plot. 8 of the 8 rooms sit under 3.5 m, which rules out flown LED there and limits ground-stacked walls to about 6 rows of 500 mm tile.
Data source
Published dimensions. Dimensions from the venue's published meeting-space specifications (source). Rooms drawn as boxes use published length x width; square rooms were derived from published area only, so treat their shape as approximate. Venue managers: send a floor plan to upgrade your listing to production-ready.