Tanner Preserve AV
Home / Venues / Brisbane Convention & Exhibition Centre / Meeting Room A2

Meeting Room A2 at Brisbane Convention & Exhibition Centre

Published dimensions

Meeting Room A2 is 15.7 x 7.8 m (52 x 26 ft), 123 m² (1,319 sq ft), with a 3.6 m (12 ft) ceiling.

Open in 3D previz

Plan view

15.7 m / 52 ft7.8 m / 26 ft grid 1 m

LED wall that fits

Under a 3.6 m ceiling with 1.5 m trim and 0.3 m clearance you get 3 rows of 500 mm tile flown, which is tight; ground-stack or go lower on trim. Along the 15.7 m wall a Absen A2 Pro wall runs 25 x 3 (4200 x 504 px, 750 kg, 13.9 kW).

PanelPitchWall (cols x rows)SizeResolutionWeightPower (max)
9thPanel DW1.9 S Pro1.875 mm20 x 5 = 10012 x 1.7 m6400 x 900480 kg / 1,058 lb25.4 kW, 122 A @ 208 V
Absen A2 Pro2.97 mm25 x 3 = 7512.5 x 1.5 m4200 x 504750 kg / 1,653 lb13.9 kW, 67 A @ 208 V
Absen A3 Pro3.9 mm25 x 3 = 7512.5 x 1.5 m3200 x 384713 kg / 1,571 lb12 kW, 58 A @ 208 V

Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.

Seating estimate

After a 12 x 7 m stage, Meeting Room A2 holds about 85 theater seats, 35 banquet seats at rounds of 10, or 24 classroom seats. Back row in theater is roughly 8.7 m from the downstage edge; the previz checks whether the bottom of the wall clears the heads in front.

Other rooms at Brisbane Convention & Exhibition Centre

Published dimensions (source), fetched 2026-09-05. All rooms at Brisbane Convention & Exhibition Centre · Venues in Brisbane