The TRACK at New Balance
The TRACK at New Balance in Boston lists 6 event spaces totaling 2,281 m² (24,557 sq ft). The largest is Warm Up Track at 47.2 x 47.2 m (155 x 155 ft) with a 3.1 m (10 ft) ceiling. The tallest ceiling on the property is 3.1 m (10 ft).
Open Warm Up Track in 3D previzRooms
| Room | Floor | L x W (m) | L x W (ft) | Area | Ceiling | Rig pts | Data |
|---|---|---|---|---|---|---|---|
| Warm Up Track | 47.2 x 47.2 | 155 x 155 | 2,228 m² / 23,980 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Conference Room | 7 x 7.6 | 23 x 25 | 53 m² / 573 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Concourse | 0.3 x 0.3 | 1 x 1 | 0 m² / 1 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Multi-purpose Room | 0.3 x 0.3 | 1 x 1 | 0 m² / 1 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Private Suites | 0.3 x 0.3 | 1 x 1 | 0 m² / 1 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Track Surface | 0.3 x 0.3 | 1 x 1 | 0 m² / 1 sq ft | 3.1 m / 10 ft | Published dimensions |
What fits in Warm Up Track
With a 3.1 m ceiling, a flown wall of Absen A2 Pro (2.97 mm) runs 75 tiles wide by 2 high (150 tiles, 37.5 x 1 m, 12600 x 336 px) once you keep 1.5 m of trim under the bottom edge. That wall weighs about 1,500 kg and draws up to 27.8 kW (133 A at 208 V). Floor space after a 12 x 7 m stage seats roughly 4,764 theater, 1,948 banquet, or 1,339 classroom. The previz lets you move the wall, change the tile, and check sightlines from the back row.
| Panel | Pitch | Wall (cols x rows) | Size | Resolution | Weight | Power (max) |
|---|---|---|---|---|---|---|
| 9thPanel DW1.9 S Pro | 1.875 mm | 62 x 3 = 186 | 37.2 x 1 m | 19840 x 540 | 893 kg / 1,968 lb | 47.2 kW, 227 A @ 208 V |
| Absen A2 Pro | 2.97 mm | 75 x 2 = 150 | 37.5 x 1 m | 12600 x 336 | 1,500 kg / 3,307 lb | 27.8 kW, 133 A @ 208 V |
| Absen A3 Pro | 3.9 mm | 75 x 2 = 150 | 37.5 x 1 m | 9600 x 256 | 1,425 kg / 3,142 lb | 24 kW, 115 A @ 208 V |
Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.
Planning notes
No rigging point data is published for this venue yet; plan on ground-supported LED or ask the venue for its rigging plot. 6 of the 6 rooms sit under 3.5 m, which rules out flown LED there and limits ground-stacked walls to about 6 rows of 500 mm tile.
Data source
Published dimensions. Dimensions from the venue's published meeting-space specifications (source). Rooms drawn as boxes use published length x width; square rooms were derived from published area only, so treat their shape as approximate. Venue managers: send a floor plan to upgrade your listing to production-ready.