CityCube Berlin
CityCube Berlin in Berlin lists 20 event spaces totaling 13,707 m² (147,542 sq ft). The largest is Hall B (Level 2) at 87 x 68 m (285 x 223 ft) with a 12 m (39 ft) ceiling. The tallest ceiling on the property is 12 m (39 ft).
Open Hall B (Level 2) in 3D previzRooms
| Room | Floor | L x W (m) | L x W (ft) | Area | Ceiling | Rig pts | Data |
|---|---|---|---|---|---|---|---|
| Hall B (Level 2) | 87 x 68 | 285 x 223 | 5,916 m² / 63,679 sq ft | 12 m / 39 ft | Published dimensions | ||
| Copy of Hall A8 (Level 1) | 31.9 x 31.9 | 105 x 105 | 1,018 m² / 10,953 sq ft | 6.8 m / 22 ft | Published dimensions | ||
| Hall A8 (Level 1) | 31.9 x 31.9 | 105 x 105 | 1,018 m² / 10,953 sq ft | 6.8 m / 22 ft | Published dimensions | ||
| Hall A6 (Level 1) | 30.6 x 30.6 | 100 x 100 | 936 m² / 10,079 sq ft | 6.8 m / 22 ft | Published dimensions | ||
| 17 offices and suites (Level 3) | 25.5 x 25.5 | 84 x 84 | 650 m² / 7,000 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Hall A1 (Level 1) | 23 x 23 | 75 x 75 | 529 m² / 5,694 sq ft | 6.8 m / 22 ft | Published dimensions | ||
| Hall A3 (Level 1) | 23 x 23 | 75 x 75 | 529 m² / 5,694 sq ft | 6.8 m / 22 ft | Published dimensions | ||
| Hall A5 (Level 1) | 23 x 23 | 75 x 75 | 529 m² / 5,694 sq ft | 6.8 m / 22 ft | Published dimensions | ||
| Hall A7 (Level 1) | 23 x 23 | 75 x 75 | 529 m² / 5,694 sq ft | 6.8 m / 22 ft | Published dimensions | ||
| Hall A2 (Level 1) | 22 x 22 | 72 x 72 | 484 m² / 5,210 sq ft | 6.8 m / 22 ft | Published dimensions | ||
| Hall A4 (Level 1) | 22 x 22 | 72 x 72 | 484 m² / 5,210 sq ft | 6.8 m / 22 ft | Published dimensions | ||
| 13 event offices (Entrance Level) | 13.3 x 13.3 | 44 x 44 | 177 m² / 1,904 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Meeting Room M1 (Level 3) | 13 x 13 | 43 x 43 | 169 m² / 1,819 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Meeting Room M8 (Level 3) | 13 x 13 | 43 x 43 | 169 m² / 1,819 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Meeting Room M2 (Level 3) | 11.3 x 11.3 | 37 x 37 | 128 m² / 1,375 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Meeting Room M4 (Level 3) | 11.3 x 11.3 | 37 x 37 | 128 m² / 1,375 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Meeting Room M6 (Level 3) | 11.3 x 11.3 | 37 x 37 | 128 m² / 1,375 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Meeting Room M3 (Level 3) | 7.9 x 7.9 | 26 x 26 | 62 m² / 672 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Meeting Room M5 (Level 3) | 7.9 x 7.9 | 26 x 26 | 62 m² / 672 sq ft | 3.1 m / 10 ft | Published dimensions | ||
| Meeting Room M7 (Level 3) | 7.9 x 7.9 | 26 x 26 | 62 m² / 672 sq ft | 3.1 m / 10 ft | Published dimensions |
What fits in Hall B (Level 2)
With a 12 m ceiling, a flown wall of Absen A2 Pro (2.97 mm) runs 139 tiles wide by 20 high (2780 tiles, 69.5 x 10 m, 23352 x 3360 px) once you keep 1.5 m of trim under the bottom edge. That wall weighs about 27,800 kg and draws up to 514.3 kW (2473 A at 208 V). Floor space after a 12 x 7 m stage seats roughly 12,960 theater, 5,301 banquet, or 3,645 classroom. The previz lets you move the wall, change the tile, and check sightlines from the back row.
| Panel | Pitch | Wall (cols x rows) | Size | Resolution | Weight | Power (max) |
|---|---|---|---|---|---|---|
| 9thPanel DW1.9 S Pro | 1.875 mm | 116 x 30 = 3480 | 69.6 x 10.1 m | 37120 x 5400 | 16,704 kg / 36,826 lb | 883.9 kW, 4250 A @ 208 V |
| Absen A2 Pro | 2.97 mm | 139 x 20 = 2780 | 69.5 x 10 m | 23352 x 3360 | 27,800 kg / 61,288 lb | 514.3 kW, 2473 A @ 208 V |
| Absen A3 Pro | 3.9 mm | 139 x 20 = 2780 | 69.5 x 10 m | 17792 x 2560 | 26,410 kg / 58,223 lb | 444.8 kW, 2138 A @ 208 V |
Wall sizing assumes 1.5 m trim to the bottom edge, 0.3 m clearance under the ceiling, and a wall no wider than 80% of the longest wall. Weight and power are tile totals from the panel spec sheet; add processing, rigging, and cable.
Planning notes
No rigging point data is published for this venue yet; plan on ground-supported LED or ask the venue for its rigging plot. 10 of the 20 rooms sit under 3.5 m, which rules out flown LED there and limits ground-stacked walls to about 6 rows of 500 mm tile.
Data source
Published dimensions. Dimensions from the venue's published meeting-space specifications (source). Rooms drawn as boxes use published length x width; square rooms were derived from published area only, so treat their shape as approximate. Venue managers: send a floor plan to upgrade your listing to production-ready.